Parameter 13: Motion Group Control Requirement
Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light
Size: 2 Byte, Default Value: 30000
Setting
Description
0 - 30000
Set threshold of Light/Lux
Parameter 14: Over Humidity Group Threshold (Group5)
Set threshold of humidity. If measured humidity >= (this value), send BASIC_SET (0xFF) to associated devices through group5. If measured humidity < (this value)
send BASIC_SET (0x00) to associated devices through group5.
Size: 1 Byte, Default Value: 60
Setting
Description
0 - 100
Set threshold of humidity.
Parameter 15: Under Humidity Group Threshold (Group6)
Set threshold of humidity. If measure humidity(this value) send BASIC_SET (0x00) to associated devices through group6.
Size: 1 Byte, Default Value: 40
Setting
Description
0 - 100
Set threshold of humidity.
Parameter 16: Over Heat Group Threshold (Group3)
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is
determined by Param64) send BASIC_SET (0xFF) to associated devices. If measured temperature<(this value) send BASIC_SET (0x00) to associated devices.
E.g. Value 239 means 23.9 C. Value 750 means 75.0 F.
Size: 2 Byte, Default Value: 239
Setting
Description
-400 - 850
Set threshold of temperature
Parameter 17: Under Heat Group Threshold (Group4)