background image

1.
2.

3.
4.

Put your primary controller into device removal mode.
Unlock your Sensor from the Back Mount plate and take the 
Sensor unit near to your primary controller.
Press the Action Button on your Sensor.
If your Door Window Sensor has been successfully removed 
from your Z-Wave network, its Status LED will fast blink for 8 
seconds and then slow blink for 3 seconds when you press 
the Action Button again. If the removing was unsuccessful, 
the Status LED will fast blink for 2 seconds and then be solid 
for 2 seconds when you press the Action Button, repeat the 
above steps.

If  you  want  your  Sensor  as  a  non-security  device  in  your 

Z-

Wave

 network, you just need to press the Action Button once 

on Door Window Sensor when you use a controller/gateway 
to add/include your Sensor.

Security or Non-security feature of your Sensor in 

Z-

Wave 

network.

Including Door/Window Sensor as a non-secure device:

In order to take full advantage of all functionality the Door 
Window  Sensor,  you  may  want  your  Sensor  is  a  security 
device that uses secure/encrypted message to communicate in 
Z-

Wa

ve network, so a security enabled controller/gateway is 

needed  for  the  Door  Window  Sensor  to  be  used  as  a 
security device. 

Including Door/Window Sensor as a secure device:

gateway. To do this, please refer to the part of their respective 
manuals that tell you how to remove devices from your network.

Содержание Aeotec Z-Stick Gen5

Страница 1: ...View the expanded manual http aeotec com support GEN5...

Страница 2: ...s it all in a smaller more elegant design crafted to suit any home s decor The Door Window Sensor is also a security Z Wave device that supports Over The Air OTA for firmware updates Familiarize yours...

Страница 3: ...utton Screw Holes Hitch Hitch Hole Orientation Dimples Magnet Unit Action Button Security Tamper Switch Battery Holder Double Sided Mounting Tape Sticking Area Magnet Unit Outer Sehll Security Tamper...

Страница 4: ...o the surface Whether it s for security or intelligence purposes your sensor 1 2 3 4 Should be affixed indoors and away from sources of moisture Placed within 30 meters of another Z Wave device that i...

Страница 5: ...h both mounting plates to the respective surface using the two 20mm screws provided If you are using double sided tape wipe the two surfaces clean of any oil or dust with a damp towel When the surface...

Страница 6: ...ur sensor to its plates 1 2 3 4 1 2 Let your Z Wave primary controller gateway enter into adding inclusion mode Take your Sensor near to your primary controller Press the Action Button once on your Se...

Страница 7: ...d the Action Button on the back of the Sensor unit for 3 seconds then your Sensor will wake up for 10 minutes and the Status LED will fast blink while it is awake 4 In order to send your Sensor new co...

Страница 8: ...your Sensor as a non security device in your Z Wave network you just need to press the Action Button once on Door Window Sensor when you use a controller gateway to add include your Sensor Security or...

Страница 9: ...ct from has also guaranteed to assist you with any of your support needs and you can also contact them for accordingly This guarantee made by the company who you purchased the product from includes th...

Страница 10: ...f a problem Aeon Labs sole obligation under the foregoing warranty is at Aeon Labs option to repair replace or correct any such defect that was present at the time of delivery or to remove the Product...

Страница 11: ...nd Aeon Labs affiliates shareholders directors officers employees contractors agents and other representatives harmless from all demands claims actions causes of action proceedings suits assessments l...

Страница 12: ...E OF THE PRODUCTS WHETHER BASED ON NEGLIGENCE STRICT LIABILITY BREACH OF WARRANTY BREACH OF AGREEMENT OR EQUITABLE PRINCIPLES IS EXPRESSLY LIMITED TO AT AEON LABS OPTION REPLACEMENT OF OR REPAYMENT OF...

Страница 13: ...digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses...

Страница 14: ...Warning Contact your local government for information regarding the collection systems available Certifications regional Version 501012000001 AA www aeotec com Z Wave and Z Wave Plus are registered tr...

Страница 15: ...Association information Configuration parameters information...

Страница 16: ......

Страница 17: ...Go to the support page https aeotec freshdesk com support home We have extensive online resources where you can search user guides release notes and technical tips and more...

Отзывы: