background image

ACT-IR303FM, v1.0, 2003/04/06    

 

    IrFM and Fast Connect Debug/Test Suite

 

 

© Copyright 2002-2003, ACTiSYS              Page 1 of 8

   

     

ACTiSYS Confidential

 

 

 
 

Corp.  

48511 Warm Springs Blvd., Suite 206, Fremont, CA 94539     Tel: (510)490-8024,  

Fax: (510)623-7268, Website: http:\\www.actisys.com, E-mail: 

[email protected]

 

 
 
 
 
 
 
 
 

IrFM And Fast Connect Debug/Test Suite 

 

(ACT-IR303FM, v1.0, 2003/04/06) 

 
 

(c) Copyright ACTiSYS Corp. 2002-2003 

 
 
 
 
 
 
 
 
 
 

April 06, 2003 

 
 
 
 
 

Содержание IR303FM

Страница 1: ... Page 1 of 8 ACTiSYS Confidential Corp 48511 Warm Springs Blvd Suite 206 Fremont CA 94539 Tel 510 490 8024 Fax 510 623 7268 Website http www actisys com E mail actisys actisys com IrFM And Fast Connect Debug Test Suite ACT IR303FM v1 0 2003 04 06 c Copyright ACTiSYS Corp 2002 2003 April 06 2003 ...

Страница 2: ... 0 1 3 12 24 2002 Added IrFM Implementation Strategy in Sec E Rev 0 1 4 12 25 2002 Editorial changes Added IR103SLi IR8203LM5VP photo in Sec E 2 Rev 0 1 5 01 08 2003 Moved Rev History to page 2 Updated model name IR8200LA M Rev 1 0 04 06 2003 Added extra IrFM simulation test features Added script files configuration files and TinyTP text file ACTiSYS reserves the right to make changes without furt...

Страница 3: ...t Simulator ACTiLinkPOS and IR223L 5 C 3 IrFM And Fast Connect Recording Program ACT IR912SW and IR910D 5 C 4 IrFM And Fast Connect Recording Analyzer ACT IR913SW 5 D IrLAP IrFM And Fast Connect IrFM Block Diagram 6 E IrFM Implementation Strategy 7 E 1 IrFM Implementation Plan 1 Port Full IrDA and IrFM Protocol Layers 7 E 2 IrFM Implementation Plan 2 Partition IrFM from IrDA Protocol and IrPHY 7 F...

Страница 4: ...d Fast Connect for IrFM PTD and POS 3 Speeds up the IrDA certification process 4 Speeds up time to market C Hardware Software Included in the Suite 1 IrFM PTD with Fast Connect Simulator Hardware IR103SP and SW ACTiLinkPTD 2 IrFM POS with Fast Connect Simulator Hardware IR103SL and SW ACTiLinkPOS 3 IrFM with Fast Connect Recording Hardware IR910D and Software IR912SW 4 IrFM with Fast Connect Recor...

Страница 5: ...les direct the POS Simulator to test PTD according to IrDA IrFM Test Spec C 3 IrFM With Fast Connect Recording Program ACT IR912SW and IR910D 1 This program runs in a PC not included and records the conversation between PTD and POS at data rates of 9 6 19 2 38 4 57 6 or 115 2 kb s It changes data rate automatically to follow the conversation 2 This program uses a special IrDA dongle ACT IR910D Dua...

Страница 6: ...MP level That is only the payload of IrLAP I frame is shown This includes the IrLMP Destination IrLMP Source TinyTP and all upper layer data 5 The fourth text file has only the details at the TinyTP level 6 All frames in the above 4 text files are assigned arbitrary but unique sequential numbers for easy cross referencing between these 4 text files D IrFM and IrDA Block Diagram ACT IR303FM only ad...

Страница 7: ...updates POS manufacturer may need to re do 1 3 above again each time to meet IrReady spec 6 IrLAP with Fast Connect may not be optimized to perform fast enough connection E 2 IrFM Implementation Plan 2 To Partition IrFM from IrDA Protocol and IrPHY 1 Port IrFM and IrOBEX protocol layers onto the POS microprocessor 2 Use ready made and pre tested IrDA FastConnect internal PCB or chip set which incl...

Страница 8: ...0 IrDA Dec 2002 IrFM OBEX Test Specification Version 1 0 IrDA Dec 2002 IrFM Qualification Program Version 0 3 IrDA Nov 2002 IrFM Lower Layers Test Spec Version 0 1 April 2003 F 3 IrDA Protocol Spec Serial Infrared Link Access Protocol IrLAP Version 1 1 IrDA Jun 1996 Link Management Protocol IrLMP Version 1 1 IrDA Jan 1996 Tiny TP Version 1 1 IrDA Oct 1996 Object Exchange Protocol IrOBEX Version 1 ...