background image

6

 

Infrared Thermometer Model CA870

CHAPTER 3

SPECIFICATIONS

3.1  Electrical Specifications

Temperature Range:

 -4° to 500°F (-20° to 260°C)

Display Resolution:

 1°F/°C

Accuracy:

±2% of reading or ±6°F (3°C), whichever is greater @ 64.4 to 82.4°F (18 

to 28°C) ambient operating temperature.

Temperature Coefficient:

Changes in accuracy operating temperature above 82.4°F (28°C) or below 

64.4°F (18°C): ±0.2% of reading or ±0.36°F (0.2°C), whichever is greater.

Response Time:

 1 second

Spectral Response:

 6 to 14μm nominal

Emissivity:

 Preset @ 0.95

Detection Element:

 Thermopile

Optical Lens:

 Fresnel Lens

Field of View (FOV) ratio:

10:1  (Distance : Diameter)
The  FOV  is  the  ratio  of  the 

distance  to  the  target  to  the 

target  diameter.  When  the 

target diameter is small, it is 

important  to  bring  the  ther-

mometer closer to the target 

to ensure that only the target 

is  measured,  excluding  the 

surroundings. Remember that the measurement size is one-tenth the dis-

tance to the target. For example, if the thermometer is at 10", then the size 

measured is 1".

25Ø

500

250

50Ø

75Ø

100Ø

750

1000

Distance to

object (mm)

Содержание CA870

Страница 1: ...INFRARED THERMOMETER CA870 E N G L I S H User Manual Auto OFF...

Страница 2: ...f the instrument Please record this number and purchase date for your records INFRARED THERMOMETER MODEL CA870 CATALOG 2121 30 SERIAL _ _______________________________________________ PURCHASE DATE __...

Страница 3: ...2 3 Back light Button 5 3 SPECIFICATIONS 6 3 1 Electrical Specifications 6 3 2 General Specifications 7 3 3 Safety Specifications 7 4 OPERATION 8 4 1 Measurement Considerations 8 4 2 Recommendations b...

Страница 4: ...perfectly clean Do not touch the sensor when taking measurements as it may affect the readings When the meter is exposed to sudden temperature changes hot or cold allow 20 minutes of stabilization bef...

Страница 5: ...issing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing c...

Страница 6: ...sensor with a fixed emmisivity of 0 95 The thermometer is simply aimed at the target to be measured without any physical contact non contact temperature measurement The thermometer is supplied with a...

Страница 7: ...s before auto matically shuting OFF 2 2 2 C F Button Pressing this button makes the thermometer toggle between F and C The selected temperature type is displayed in the lower right hand corner of the...

Страница 8: ...Response Time 1 second Spectral Response 6 to 14 m nominal Emissivity Preset 0 95 Detection Element Thermopile Optical Lens Fresnel Lens Field of View FOV ratio 10 1 Distance Diameter The FOV is the...

Страница 9: ...y removed Auto Power Off 15 seconds approx Altitude 2000m max Input Protection 24VDC or 24rms maximum input voltage on any combi nation of inputs Battery Standard 9V battery NEDA 1604 6LR61 or equival...

Страница 10: ...on sensor through an optical system This system includes an optical lens which is transparent to infrared radiation and a 5 3 m cut off filter The output signal from the infrared radiation sensor is i...

Страница 11: ...is based upon the object material type and its surface finish Emissivity values range from 0 10 for a very reflective object to 1 00 for a black body Factory set emissivity value of 0 95 will cover 90...

Страница 12: ...the LCD display when replacement is needed Replace with a standard 9 volt battery NEDA 1604 6LR61 To replace the battery Turn the meter OFF Remove the rubber holster Remove the screw from the back of...

Страница 13: ...cludes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax...

Страница 14: ...ay return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty materi...

Страница 15: ...Notes...

Страница 16: ......

Отзывы: