Warning 

 

•  Thermometers  are  not  designed  to  touch  live  electrical  sam-

ples.

•  To prevent sensor damage, do not point the sensor lens directly 

at the sun or any other source of strong infrared light.

•  Do not place the infrared thermometer directly on or close to 

objects at temperatures exceeding 158°F (70°C)

•  To prevent measurement errors, do not expose the thermom-

eter to strong electrical or electromagnetic fields.

•  To  prevent  sensor  damage  and  erroneous  readings,  do  not 

put the sensor lens into contact with any body or foreign/loose 

material when measuring. Keep the sensor perfectly clean.

•  Do not touch the sensor when taking measurements as it may 

affect the readings.

•  When  the  meter  is  exposed  to  sudden  temperature  changes 

(hot or cold), allow 20 minutes of stabilization before taking a 

reading.

•  Be certain there is no condensation on the lens prior to taking 

measurements. Allow 10 minutes for condensation to dissipate 

as needed.

•  The Model CA870 is not waterproof or dust-proof. Take neces-

sary precautions to protect it in wet or dusty environments.

1.1  International Electrical Symbols

This  symbol  on  an  instrument  indicates  a  WARNING  and  that 

the operator must refer to the user manual for instructions before 

operating  the  instrument.  In  a  manual,  the  symbol  preceding 

instructions indicates that if the instructions are not followed, bodily 

injury, installation/sample and product damage may result.

Содержание CA870

Страница 1: ...INFRARED THERMOMETER CA870 E N G L I S H User Manual Auto OFF...

Страница 2: ...f the instrument Please record this number and purchase date for your records INFRARED THERMOMETER MODEL CA870 CATALOG 2121 30 SERIAL _ _______________________________________________ PURCHASE DATE __...

Страница 3: ...2 3 Back light Button 5 3 SPECIFICATIONS 6 3 1 Electrical Specifications 6 3 2 General Specifications 7 3 3 Safety Specifications 7 4 OPERATION 8 4 1 Measurement Considerations 8 4 2 Recommendations b...

Страница 4: ...perfectly clean Do not touch the sensor when taking measurements as it may affect the readings When the meter is exposed to sudden temperature changes hot or cold allow 20 minutes of stabilization bef...

Страница 5: ...issing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing c...

Страница 6: ...sensor with a fixed emmisivity of 0 95 The thermometer is simply aimed at the target to be measured without any physical contact non contact temperature measurement The thermometer is supplied with a...

Страница 7: ...s before auto matically shuting OFF 2 2 2 C F Button Pressing this button makes the thermometer toggle between F and C The selected temperature type is displayed in the lower right hand corner of the...

Страница 8: ...Response Time 1 second Spectral Response 6 to 14 m nominal Emissivity Preset 0 95 Detection Element Thermopile Optical Lens Fresnel Lens Field of View FOV ratio 10 1 Distance Diameter The FOV is the...

Страница 9: ...y removed Auto Power Off 15 seconds approx Altitude 2000m max Input Protection 24VDC or 24rms maximum input voltage on any combi nation of inputs Battery Standard 9V battery NEDA 1604 6LR61 or equival...

Страница 10: ...on sensor through an optical system This system includes an optical lens which is transparent to infrared radiation and a 5 3 m cut off filter The output signal from the infrared radiation sensor is i...

Страница 11: ...is based upon the object material type and its surface finish Emissivity values range from 0 10 for a very reflective object to 1 00 for a black body Factory set emissivity value of 0 95 will cover 90...

Страница 12: ...the LCD display when replacement is needed Replace with a standard 9 volt battery NEDA 1604 6LR61 To replace the battery Turn the meter OFF Remove the rubber holster Remove the screw from the back of...

Страница 13: ...cludes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax...

Страница 14: ...ay return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty materi...

Страница 15: ...Notes...

Страница 16: ......

Отзывы: