Infrared Thermometer Model CA870 

11

 

Repair and Calibration

To ensure that your instrument meets factory specifications, we recommend 

that it be scheduled back to our factory Service Center at one-year intervals 

for recalibration, or as required by other standards or internal procedures.

For instrument repair and calibration:

You must contact our Service Center for a Customer Service Authorization 

Number (CSA#). This will ensure that when your instrument arrives, it will be 

tracked and processed promptly. Please write the CSA# on the outside of the 

shipping  container.  If  the  instrument  is  returned  for  calibration,  we  need  to 

know if you want a standard calibration, or a calibration traceable to N.I.S.T. 

(Includes calibration certificate plus recorded calibration data). 

Ship To:

  Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments

 

15 Faraday Drive

 

Dover, NH 03820 USA

 

Phone: (800) 945-2362  (Ext. 360)

 

 

(603) 749-6434  (Ext. 360)

 

Fax:  (603) 742-2346 or (603) 749-6309

 

E-mail: [email protected]

(Or contact your authorized distributor)
Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are 

available.

NOTE: You must obtain a CSA# before returning any instrument.

Technical and Sales Assistance

If you are experiencing any technical problems, or require any assistance with 

the proper operation or application of your instrument, please call, mail, fax or 

e-mail our technical support team:

 

Chauvin Arnoux

®

, Inc. d.b.a. AEMC

®

 Instruments

 

200 Foxborough Boulevard

 

Foxborough, MA 02035 USA

 

Phone: (800) 343-1391

 

 

(508) 698-2115

 

Fax:  (508) 698-2118

 

E-mail: [email protected] 

 

www.aemc.com

NOTE: Do not ship Instruments to our Foxborough, MA address.

Содержание CA870

Страница 1: ...INFRARED THERMOMETER CA870 E N G L I S H User Manual Auto OFF...

Страница 2: ...f the instrument Please record this number and purchase date for your records INFRARED THERMOMETER MODEL CA870 CATALOG 2121 30 SERIAL _ _______________________________________________ PURCHASE DATE __...

Страница 3: ...2 3 Back light Button 5 3 SPECIFICATIONS 6 3 1 Electrical Specifications 6 3 2 General Specifications 7 3 3 Safety Specifications 7 4 OPERATION 8 4 1 Measurement Considerations 8 4 2 Recommendations b...

Страница 4: ...perfectly clean Do not touch the sensor when taking measurements as it may affect the readings When the meter is exposed to sudden temperature changes hot or cold allow 20 minutes of stabilization bef...

Страница 5: ...issing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing c...

Страница 6: ...sensor with a fixed emmisivity of 0 95 The thermometer is simply aimed at the target to be measured without any physical contact non contact temperature measurement The thermometer is supplied with a...

Страница 7: ...s before auto matically shuting OFF 2 2 2 C F Button Pressing this button makes the thermometer toggle between F and C The selected temperature type is displayed in the lower right hand corner of the...

Страница 8: ...Response Time 1 second Spectral Response 6 to 14 m nominal Emissivity Preset 0 95 Detection Element Thermopile Optical Lens Fresnel Lens Field of View FOV ratio 10 1 Distance Diameter The FOV is the...

Страница 9: ...y removed Auto Power Off 15 seconds approx Altitude 2000m max Input Protection 24VDC or 24rms maximum input voltage on any combi nation of inputs Battery Standard 9V battery NEDA 1604 6LR61 or equival...

Страница 10: ...on sensor through an optical system This system includes an optical lens which is transparent to infrared radiation and a 5 3 m cut off filter The output signal from the infrared radiation sensor is i...

Страница 11: ...is based upon the object material type and its surface finish Emissivity values range from 0 10 for a very reflective object to 1 00 for a black body Factory set emissivity value of 0 95 will cover 90...

Страница 12: ...the LCD display when replacement is needed Replace with a standard 9 volt battery NEDA 1604 6LR61 To replace the battery Turn the meter OFF Remove the rubber holster Remove the screw from the back of...

Страница 13: ...cludes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax...

Страница 14: ...ay return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty materi...

Страница 15: ...Notes...

Страница 16: ......

Отзывы: