background image

11

Replace the dead battery by a 9V battery (6F22 or 6LF22)
Replace the defective fuses respecting their value and their type
:
- Fuse 0.5A HBC (500V - 10kA - min 6.3 x 32mm)
- Fuse 12A HBC (600V min - 300kA - 10.3 x 38mm)

12-2 Storage

If the multimeter is not to be used for a period of 60 days or more,
remove the battery and store separately.

12-3 Cleaning

The multimeter must be disconnected from any

electrical source.

To clean the case, use a cloth slightly moistened with soapy water.
Rinse with a damp cloth. Then, dry rapidly with a cloth or in a hot air
stream.

12-4 Repair and calibration

To guarantee that your instrument complies with the factory
specifications, we recommend that the Model C.A 5230 be submitted
to our factory service center at one-year intervals for recalibration,
or as required by other standards.
For instrument repair and/or calibration, please call our factory, toll-
free, at 

(800) 945-AEMC

 (800-945-2362):

CHAUVIN ARNOUX, Inc.
d.b.a. AEMC

 

Instruments

15 Faraday Drive
Dover, NH 03820 USA
Tel : (800)  954-2362

(603) 749-6434

Fax : (603) 742-2346

(Or contact your authorized distributor)
Costs for repair, standard calibration, and calibration traceable to
N.I.S.T. are available upon request. Overseas customers must receive
written authorization before returning any instrument.

12-5

Technical and Sales Assistance

If you are experiencing any technical problems, or require any
assistance with the proper use or application of this instrument,
please call our technical hotline:

CHAUVIN ARNOUX, Inc.
d.b.a. AEMC

 

Instruments

200 Foxborough Blvd.
Foxborough, MA 02111 USA
Tel : (800)  343-1391

(508) 698-2115

Fax : (508) 698-2118

www.aemc.com

Содержание C.A 5230

Страница 1: ...r manual DigitalMultimeter Model C A 5230 MULTIMETER Hz V V OFF mA 10A M I N MAX RANGE HOLD ZERO 10A 500mA FUSED 10A max FUSED C A 5230 COM 600V CAT III MAX ZERO n u F Mk Hz HOLD 30 20 10 0 40 RMS MUL...

Страница 2: ...instrument and invalidation of the warranty Fuse 0 5A HBC 500V min 10kA 6 3 x 32mm Fuse 12A HBC 600V min 300kA 10 3 x 38mm Never use on voltage to earth circuits above 600V with a voltage surge categ...

Страница 3: ...rofessionals in electricity true rms measurement RMS digital 4000 counts and 42 segment bargraph automatic or manual range selection auto off after 30 minutes without action on a control or function p...

Страница 4: ...measurement HOLD On capacitancemeter function zero reset by press without releasing Permanent operation possibility of suppressing auto off by pressing this button without releasing before operating...

Страница 5: ...lead for the 10AAC DC ranges 3 DC AND AC VOLTAGE Connect the leads to the multimeter and connect it in parallel to the circuit to be tested Place the selector switch on the voltmeter function VAC DC A...

Страница 6: ...tton for this function selects the triggering threshold 10mV for 100Hz 1kHz and 10kHz ranges 400mV for 100kHz and 400kHz ranges 2 Note Ifthefrequencyappliedis99 99kHz thedecimalpointoscillatesbetween9...

Страница 7: ...Connect the leads to the multimeter and to the terminals of the component to be tested Place the selector switch on the function in forward direction the display gives the value of the junction in vo...

Страница 8: ...ges manually MIN MAX to read the min or max values to light the display 4nF 40nF 400nF 4 F 40 F 1 Resolution 1pF 10pF 100pF 1nF 10nF Accuracy 2 R 150cts 2 of reading 8cts Protection 500V mns 750 peak...

Страница 9: ...6 F 22 500 h with alkaline battery type 6 LF22 Low battery indication Auto off after 30 minutes Note Switch on again via the OFF position 9 3 Buzzer Continuous beep for the continuity test Intermitte...

Страница 10: ...el MR410 400AAC 600ADC Cat 1200 70 AmpFLEX model 1000 24 1 1 1000AAC Cat 2112 39 Replacement leads Cat 2118 66 Soft carrying case Cat 2118 65 Replacement shockproof case Cat 2980 15 Fuse set of 10 0 5...

Страница 11: ...our factory service center at one year intervals for recalibration or as required by other standards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945...

Отзывы: