background image

5

     

   FUNCTION SELECTOR SWITCH

 OFF

Off position

 

 V~

AC voltages up to 600V in rms value

  V

...

DC voltages up to 600V

  

Hz

Frequencies of voltages up to 400kHz

 

 

Continuity sound test for a resistance R 

 40

, and

measurements of resistances up to 40M

Note: 

The continuity test 

 is selected automatically

when the instrument is switched on.

  

Diode test. Measurement of the voltage of the junction in
forward direction

   

Capacitances up to 40µF

  mA

Current ranges up to 400mA

AC/DC

 (via the + terminal)

   A

10A

AC/DC

 current ranges (via the 10A terminal)

     

   TERMINALS

Ø 4mm safety terminals

  COM: 

common, black

  +:

 red

  10A: 

red lead for the 10A

AC/DC

 ranges

3 - DC AND AC VOLTAGE

  

Connect the leads to the multimeter and connect it in parallel to the
circuit to be tested.

  

Place the selector switch on the voltmeter function V

AC/DC

  

Automatic selection of the range: read the value measured.

  

Freeze the value by pressing the HOLD button.

 If necessary, press the following buttons:

  

RANGE to select the ranges manually

  

MIN-MAX to read the min or max values

  

 to light the display

V

AC/DC

400mV 

(1)

4V

40V

400V

600V 

(2)

Digital

0.1mV

1mV

10mV

100mV

1V

resolution

Bargraph

10mV

100mV

1V

10V

100V

resolution

Impedance

100M

10M

9.1M

Accuracy

± 0.25% of Reading  ±1ct

on DC

Accuracy

± 1.5% R

± 1% of Reading ±3cts

on AC

±5cts

Permitted

600Vrms and 1000V peak

overload

(1) Accessible by the RANGE button. Min measurement : 20mV
(2) Crest factor FC 

 3

Содержание C.A 5230

Страница 1: ...r manual DigitalMultimeter Model C A 5230 MULTIMETER Hz V V OFF mA 10A M I N MAX RANGE HOLD ZERO 10A 500mA FUSED 10A max FUSED C A 5230 COM 600V CAT III MAX ZERO n u F Mk Hz HOLD 30 20 10 0 40 RMS MUL...

Страница 2: ...instrument and invalidation of the warranty Fuse 0 5A HBC 500V min 10kA 6 3 x 32mm Fuse 12A HBC 600V min 300kA 10 3 x 38mm Never use on voltage to earth circuits above 600V with a voltage surge categ...

Страница 3: ...rofessionals in electricity true rms measurement RMS digital 4000 counts and 42 segment bargraph automatic or manual range selection auto off after 30 minutes without action on a control or function p...

Страница 4: ...measurement HOLD On capacitancemeter function zero reset by press without releasing Permanent operation possibility of suppressing auto off by pressing this button without releasing before operating...

Страница 5: ...lead for the 10AAC DC ranges 3 DC AND AC VOLTAGE Connect the leads to the multimeter and connect it in parallel to the circuit to be tested Place the selector switch on the voltmeter function VAC DC A...

Страница 6: ...tton for this function selects the triggering threshold 10mV for 100Hz 1kHz and 10kHz ranges 400mV for 100kHz and 400kHz ranges 2 Note Ifthefrequencyappliedis99 99kHz thedecimalpointoscillatesbetween9...

Страница 7: ...Connect the leads to the multimeter and to the terminals of the component to be tested Place the selector switch on the function in forward direction the display gives the value of the junction in vo...

Страница 8: ...ges manually MIN MAX to read the min or max values to light the display 4nF 40nF 400nF 4 F 40 F 1 Resolution 1pF 10pF 100pF 1nF 10nF Accuracy 2 R 150cts 2 of reading 8cts Protection 500V mns 750 peak...

Страница 9: ...6 F 22 500 h with alkaline battery type 6 LF22 Low battery indication Auto off after 30 minutes Note Switch on again via the OFF position 9 3 Buzzer Continuous beep for the continuity test Intermitte...

Страница 10: ...el MR410 400AAC 600ADC Cat 1200 70 AmpFLEX model 1000 24 1 1 1000AAC Cat 2112 39 Replacement leads Cat 2118 66 Soft carrying case Cat 2118 65 Replacement shockproof case Cat 2980 15 Fuse set of 10 0 5...

Страница 11: ...our factory service center at one year intervals for recalibration or as required by other standards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945...

Отзывы: