![AEMC instruments 6416 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/aemc-instruments/6416/6416_user-manual_2861034022.webp)
22
Clamp-on Ground Resistance Tester Model 6416
Menu # Indication Function
7
dAtE
Setting the Date:
■
Enter the menu by ►.
dAtE
blinks.
■
Press ▲ or ▼ to select the year. Validate by ►.
■
Press ▲ or ▼ to select the month. Validate by ►.
■
Press ▲ or ▼ to select the date.
■
Validate and return to the previous menu by ►.
NOTE:
In some locations the order of the date values is
displayed as Year, Date, Month.
8
HOUR
Setting the Time:
■
Enter the menu by ►.
HOUR
blinks.
■
Press ▲ or ▼ to select the AM/PM (A. or P.) or 24 H
display mode (24 H), which blinks. Validate by ►.
■
Press ▲ or ▼ to select the hour, which blinks
Validate by ►.
■
Press ▲ or ▼ to select the minutes value, which blinks.
■
Validate and return to the previous menu by ►.
9
USE
Selecting Standard or Advanced Operating Mode:
■
Enter the menu by ►.
USE
blinks.
■
Press ▲ or ▼ to select the Standard or Advanced
mode.
-
Advanced Mode:
The
icon is displayed.
-
Standard Mode:
Std is displayed.
■
Validate and return to the previous menu by ►.
10
FrEQ
Choosing the Test Frequency for the Impedance in
Advanced Mode:
■
Enter the menu by ►.
FrEQ
blinks.
■
Press ▲ or ▼ to select the transposition frequency of
the measured impedance from among the four possible
values: 50, 60, 128, and 2083 Hz.
■
Validate and return to the previous menu by ►.
Содержание 6416
Страница 1: ...6416 User Manual ENGLISH CLAMP ON GROUND TESTER WITH AEMC INSTRUMENTS...
Страница 45: ...Clamp on Ground Resistance Tester Model 6416 45 NOTES...
Страница 46: ...46 Clamp on Ground Resistance Tester Model 6416 NOTES...
Страница 47: ...Clamp on Ground Resistance Tester Model 6416 47 NOTES...