background image

4 to 8 Digits



 MASTER CODE                                                                                            (Location 01)

LOCATION                       MASTER CODE                   VALIDATION 

 

 

(1) LOCATION

    

  

Key in Location 

(2) MASTER CODE

(3) VALIDATION

Master Code is the authorization code for setting the system to programming mode. It is 

NOT

 

an User Code operating the output relays.

The Master Code can be 4 to 8 digits. 

When a new master code is keyed in and confirmed, the old master code is replaced.

The master code is also the 

Link-up Code

 between the keypad and the optional decoder in 

Split-decoded operation.

17

44

(2)

(1)

(3)

Press       key once. Two-beep confirms the entry.

Example: 

Set a Master Code “2 2 3 3” ----



 SUPER USER CODE                                                                                    (Location 02)

The Super User Code has TWO functions. It is prepared to operate the three outputs and make 

operation of inhibit enable / disable to those outputs.

(1) LOCATION

      Key in Location

(2) SUPER USER CODE

      The Super User Code can be 4 to 8 digits.

      When a new Super User Code is keyed in and confirmed, the old one is replaced.

(3) VALIDATION

      Pressing 

 key to confirm code entry.      

Example: 

a) Set a Super User Code “2 5 8 0” ----
b) Deleted a Super User Code from memory: Key in the Location number and #. ----

4 to 8 Digits



(1)

(2)

(3)

LOCATION                SUPER USER CODE                 VALIDATION   





 

 

        

 

 

 

READ CARD

(c) 003 = One of the 1,000 User IDs for the User 

Code

/Card from 000-999

(d) Read Card = Put the Card close to the card reader

(e) 6123 = The User 

Code

 to be used with the EM Card. It is for example here only.

(f ) # = Confirm the Card+Code is stored, 2 beeps

6) Record an “EM Card + Commom User Code” to Operate The Output 1 for Door Open

     

    

(a)       (b)          

(c)

                  (d)              (e)

(a) 10 = Programming Location for Output 1

(b) 4 = Programming option for EM Card + Common User Code

(c) 004 = One of the 1,000 User IDs for the User 

Code

/Card from 000-999

(d) Read Card = Put the Card close to the card reader

(e) # = Confirm the card is read, 2 beeps, the Common User Code goes to this User ID 

automatically 

(f ) A Common User Code (for example: 1 3 5 7) 

MUST

 be set at the Programming 

Location 03 

first. 

Common code can be used for all the EM Cards in this operation mode.

 

REMARK: 

If more User 

Code

s and Cards are required for Output 1, repeat the procedures (3) , (4) , (5) or (6) 

above with other User IDs, such as 005, 006, 007 --- 999 etc. Total 1,000 users are allowed. See 

Programming Location 10 for the details.

7) Close The Programming Mode

                        ---- 2 beeps

The programming mode is closed. The keypad is back to normal operation mode

OPERATION

1) Open The Door with EM Card

                        --- 2 beeps, the door is open

2) Open The Door with User Code

                                --- 2 beeps, the door is open

3) Open The Door with EM CARD + User Code

                                                      --- 2 beeps, the door is open

4) Open The Door with EM CARD + Common User Code

                                                      --- 2 beeps, the door is open

READ CARD

READ CARD

READ CARD

proprietary)

5) Record an “EM Card + User Code” to Operate The Output 1 for Door Open

        (a)      (b)         (c)                   (d)                     (e)            (f)
(a) 10 = Programming Location for Output 1

(b) 3 = Programming option for EM Card + User Code. (The User Code can be repeated use or 

  



 

READ CARD

Содержание DK-2836A

Страница 1: ...B User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com Ver 201710_V5 VANDAL RESISTANT TRI TECH ACCESS CONTROL KEYPAD WITH CAR...

Страница 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Страница 3: ...means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed cir...

Страница 4: ...k Actuation Control Output Relay 2 2A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads f...

Страница 5: ...to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only on...

Страница 6: ...net Housing Die Cast Zinc Alloy Protection Bracket Faceplate Material Stainless Steel APPLICATION HINTS FOR THE AUXILIARY TERMINALS B DOOR SENS With the help of a Normally Closed door position sensor...

Страница 7: ...oded operation It is compatible with the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel wit...

Страница 8: ...ith all the input and output installations connecting to it The DK 2836 manages the data in the system with its Data I O Bus The decoder operates the door lock and the appliances directly according to...

Страница 9: ...o open during the operation While one of the doors is opened the other door keeps close until the open door is re closed It prevents the unauthorized people dashing into a protected area while the doo...

Страница 10: ...ormation 14 DATA I O Data Input Output Communication Bus Data I O port is prepared for setting up a data bus for the connection of the auxiliary reader keypads and the split decoder in system expansio...

Страница 11: ...essful Key Entry 1 Beep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Acti...

Страница 12: ...r Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the staff...

Страница 13: ...o open the door Card with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code inst...

Страница 14: ...gned for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minute after power up 2 The power up delay can be stop...

Страница 15: ...to normal opration after programming DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programmi...

Страница 16: ...system program It can not be changed in any ways 16 45 PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2...

Страница 17: ...used with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locat...

Страница 18: ...eps 3 2 8 9 is a Master Code for example here only It replaces the old master code 0000 OPERATION AND FUNCTIONS OF THE SUPER USER CODE 1 Operate Output 1 and 2 The operation of the Super User Code is...

Страница 19: ...ops in toggle with the following code entry It can be done before or during the inhibition period Door Lock Operation Resumes Start Stop in Toggle NOTE The INHIBIT LED Red is ON in inhibition and turn...

Страница 20: ...ep confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay time...

Страница 21: ...ber to enable 1 of the 6 configurations described below Momentary Contact Mode without Warning Default Momentary Contact Mode with Warning Beep Momentary Contact Mode with Warning Beep Alarm Holding C...

Страница 22: ...peration mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card 22 High Traffic Passage A short buffer time may be necessary for opening a doo...

Страница 23: ...e to prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before...

Страница 24: ...f users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Group Deletion Command 0 9 9 9 c Confi...

Страница 25: ...ation 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for...

Страница 26: ...all User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic...

Страница 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Страница 28: ...or Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work ov...

Страница 29: ...ent in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until t...

Страница 30: ...4 hour real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required i...

Отзывы: