ON-BOARD LED INDICATORS

RED / GREEN (Right)

 ---

AMBER (Centre)

 

--------- 

RED (Left)

       

----------  

 

PACIFIER TONES & THE LED SIGNALS

The buzzer and the amber LED indicator give following tones and signals respectively for system 

status:

50

DA-2801

DA-2800

Connection Terminal

The Split-decoders (Optional)

-
 AL
ARM O/P

-
 KEY ACT O/

P

-
 N.O
.

-
 COM

-
 N.C
.

-
 N.O
.

-
 COM

-
 N.C
.

-
 N.O
.

-
 COM

-
 N.C
.

-
 T

AMPER

-
 GND(

-

)

-
 DOOR SENS

-
 O/P 1 INHI

B

-
 IN

T. L

OCK

-
 DU OUT

-
 DOOR BELL IN

-
 EG IN

-
 DATA

 I/O

-
 KEYP

AD PW

R

-
 GND(

-

)

-
 12-24V DC

OPEN COLLECTOR OUTPUT

OPEN COLLECTOR OUTPUT

1A RE

LA

Y DRY CONT

ACT
S

FOR AU

XILIARY CONTROL

1A REL

AY

 DRY CONT

ACT
S

FOR AU

XILIARY CONTROL

5A RE

LA

DRY CONT

ACT
S

FOR DOOR STRIKE

OPEN COLLECTOR OUTPUT

OPEN COLLECTOR OUTPUT

INPUT/OUTPUT FOR SPLIT

-DECODED SIGNAL

S

POWER OUTPUT FOR KEYP

ADS

COMMON GROUND

POWER INPUT FOR SYSTEM

N.C. S

W

COMMON GROUN

D

N.C. S

W

N.

O. S

W

N.

O. S

W

N.

O. S

W

OUTPUT 1

OUTPUT 2 OUTPUT 3

Standard Decoder

Decoder with RF Remote Control

It lights up in Green for Output 1 activation; Red for Output 1 inhibited 

and flashing during inhibition paused.
It flashes in Standby. It shows the system status in synchronization 

with the beep tones. The standby flashing can be OFF with 

programming. See Location 73 for the details.
It lights up in Red for output 2 activation or while BELL button is 

pressed.

STATUS

TONES *

AMBER LED

1) In Programming Mode

-----

ON

2) Successful Key Entry

1 Beep

1 Flash

3) Successful Code / Card Entry

2 Beeps

2 Flashes

4) Unsuccessful Code / Card Entry

5 Beeps

5 Flashes

5) Power Up Delay

 

Continuous Beeps

Continuous Flashes

6) Output Relay Activation **

1 Second Long Beep

 

7) In Standby ***

 

-----

1 Flash in 1 Second Interval

8) System Refreshing

 

-----

Fast Flashes for 2.5 Minutes

   

 

Continuous 3 Fast Beeps

/5 secs

-----

   

 

Continuous 1 Beep/1 sec

   

 

11) Real -time-clock stopped after 

       power failure

   

 

10) Keypad link-up with Decoder Failed

   

 

)

9

Card or Code Already Stored in 

 

     System

1 Long Beep

-----

-----

-----

NOTE:

*     

* * 

 

* * *

JUMPER FOR BACK-LIT SELECTION  

         

                                                                                                                                        

1) 

Full Back-lit

 ---

 

2) 

Auto Back-lit

 

---

 

3) OFF               

---

All Pacifier Tones can be ON or OFF through the programming option at Location 71

The Output Relay Activation beep can be selected through the programming option at 

Location 72

The Standby flashing can be ON or OFF through the programming option at Location 73

The keypad gives dim backlit in standby. It 

turns to full backlit when a key button is 

pressed, then back to dim backlit 10 

seconds after the last key button is 

pressed.
The backlit is OFF in standby. It turns to 

full backlit when a key button is pressed, 

then back to OFF 10 seconds after the last 

key button is pressed.

Back-lit function disabled.

11

OTHER FACILITIES

BACK-LIT

IMPORTANT NOTE
The optional Auxiliary Readers, Reader-keypads and Split-decoders are DC 
operation. It is necessary to power the whole system with DC power supply if the 
Master Keypad is working with them for system expansion, even it is an AC/DC 
Version keypad

Содержание DK-2836A

Страница 1: ...B User Manual MK II FOR ELECTRIC LOCK INTER LOCK AND SECURITY SYSTEM INSTALLATIONS AEI PROTECT ON SYSTEMS LIMITED www apo hk com Ver 201710_V5 VANDAL RESISTANT TRI TECH ACCESS CONTROL KEYPAD WITH CAR...

Страница 2: ...User Code Common User Codes for Output 1 2 User Codes Card For Output 1 2 Examples Programming And Operation Visitor Codes For Output 1 Only Duress Codes For Outputs 1 2 Operation And Function of The...

Страница 3: ...means that no electricity is connected to it It is prepared for free connections The Relay Output contacts provided in this keypad system are dry contacts N C Normally Closed the contact is closed cir...

Страница 4: ...k Actuation Control Output Relay 2 2A Rating N C N O Contacts for External Door Bell Actuation Control A member of the Tri Tech series keypads compatible with the optional controllers reader keypads f...

Страница 5: ...to ground when duress code is entered You may use it to turn ON an LED lamp and or a small buzzer to notify a guard or connect it to a 24 hour Normally Open protection zone of an alarm system Only on...

Страница 6: ...net Housing Die Cast Zinc Alloy Protection Bracket Faceplate Material Stainless Steel APPLICATION HINTS FOR THE AUXILIARY TERMINALS B DOOR SENS With the help of a Normally Closed door position sensor...

Страница 7: ...oded operation It is compatible with the auxiliary readers AR 2802 and the auxiliary reader keypads AR 2806 AR 2807 AR 2809 Total 3 auxiliary readers or reader keypads can be connected in parallel wit...

Страница 8: ...ith all the input and output installations connecting to it The DK 2836 manages the data in the system with its Data I O Bus The decoder operates the door lock and the appliances directly according to...

Страница 9: ...o open during the operation While one of the doors is opened the other door keeps close until the open door is re closed It prevents the unauthorized people dashing into a protected area while the doo...

Страница 10: ...ormation 14 DATA I O Data Input Output Communication Bus Data I O port is prepared for setting up a data bus for the connection of the auxiliary reader keypads and the split decoder in system expansio...

Страница 11: ...essful Key Entry 1 Beep 1 Flash 3 Successful Code Card Entry 2 Beeps 2 Flashes 4 Unsuccessful Code Card Entry 5 Beeps 5 Flashes 5 Power Up Delay Continuous Beeps Continuous Flashes 6 Output Relay Acti...

Страница 12: ...r Code Operation Media 3 A secondary user code can be repeatedly used for a group of cards in a department Owner can make a proprietary department code for each department in a company Only the staff...

Страница 13: ...o open the door Card with proprietary user code approach is ideal for the area that high security is the main concern This operation mode can also report Duress Alarm by keying in the duress code inst...

Страница 14: ...gned for setting the keypad to programming mode with DAP code See the details of DAP CODE 2 8 2 8 below 1 The keypad gives continuous beeps for 1 minute after power up 2 The power up delay can be stop...

Страница 15: ...to normal opration after programming DIRECT ACCESS TO PROGRAMMING MODE WITH DAP CODE 2 8 2 8 In case the Master Code is forgotten apply the following procedures precisely to set keypad into programmi...

Страница 16: ...system program It can not be changed in any ways 16 45 PROGRAMMING SUMMARY CHART LOCATION FUNCTION ENTRY LIMITS CODE OPTIONS CODE ENTRY FACTORY DEFAULT 0 1 Master Code 4 8 Digits MASTER CODE NIL 0 2...

Страница 17: ...used with the EM Card It is for example here only f Confirm the Card Code is stored 2 beeps 6 Record an EM Card Commom User Code to Operate The Output 1 for Door Open a b c d e a 10 Programming Locat...

Страница 18: ...eps 3 2 8 9 is a Master Code for example here only It replaces the old master code 0000 OPERATION AND FUNCTIONS OF THE SUPER USER CODE 1 Operate Output 1 and 2 The operation of the Super User Code is...

Страница 19: ...ops in toggle with the following code entry It can be done before or during the inhibition period Door Lock Operation Resumes Start Stop in Toggle NOTE The INHIBIT LED Red is ON in inhibition and turn...

Страница 20: ...ep confirms the entry EXAMPLES Example 1 Set Egress Button in Momentary contact of 5 seconds with delay warning beep a b c d a Egress function programming b Momentary contact with warning c Delay time...

Страница 21: ...ber to enable 1 of the 6 configurations described below Momentary Contact Mode without Warning Default Momentary Contact Mode with Warning Beep Momentary Contact Mode with Warning Beep Alarm Holding C...

Страница 22: ...peration mode a b a Key in the Private User Code 1 2 3 4 b Confirm it with the key Output 2 activates Read Card Read Card 22 High Traffic Passage A short buffer time may be necessary for opening a doo...

Страница 23: ...e to prevent unattended leaving shoplifting and unauthorized use of the emergency exits The Intelligent Egress Button can be programmed to do something to get attention from the person on duty before...

Страница 24: ...f users including the Codes and Cards can be cleared with the following command a b c a The User Group 1 10 is selected to be cleared 20 for Group 2 b Key in the Group Deletion Command 0 9 9 9 c Confi...

Страница 25: ...ation 72 1 LOCATION Key in Location 2 FUNCTION MODES FOR OUTPUT ANNOUNCER Output announcer gives notification beep on the operation status of the outputs There are two notification modes available for...

Страница 26: ...all User Codes must be in 5 digits as well All other User Codes not in 5 digits become invalid When the number of digits reaches the system will check the User Code automatically Good for high traffic...

Страница 27: ...e code entry The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry Always set a Duress Code that is easy to remember in Panic Situation Only one number differ...

Страница 28: ...or Output 1 b Duress Code ID c The Duress Code e Entry Confirmation iii Pause the real time inhibition manually The real time inhibition can be stopped temporarily if require such as the staff work ov...

Страница 29: ...ent in emergency START STOP TIMES FOR DAILY INHIBITION OF OUTPUT 1 Location 56 Setting with start and stop times into the keypad the real time inhibition period for output 1 will recycle daily until t...

Страница 30: ...4 hour real time clock provides the daily time base for starting and stopping the function of inhibition to relay output 1 mainly for electric door lock strike No real time clock setting is required i...

Отзывы: