--------------------------------------------------------------------------------6/20--------------------------------------------------------------------------------
2.4
Connecting of the power supply cable
The reader has to be supplied with 9..30V DC. The maximum output power of the power supply has
to be 1.2 Watt. Be sure that you use the right polarity.
It is very important to power the AMP with a clean ground (without any electrical interferences).
The best way is, to use the same ground as the reading system.
2.4.1
Using the connecting cable for AMP und ARE i2 (RS232)
Power supply:
brown =
+ 9 .. 30 Volt
white =
ground
2.4.2
Using the switchboard cable for AMP (RS232)
Power supply:
brown =
+ 9 .. 30 Volt
white =
ground
Interface:
green =
RXD (Dataout AMP 4/8)
yellow =
TXD (Dataout AMP 4/8)
grey =
ground
2.4.3
Using the switchboard cable for AMP (binär)
Power supply:
brown =
+ 9 .. 30 Volt
white =
ground
binary control:
green =
B0
yellow =
B1
grey =
B2
pink =