--------------------------------------------------------------------------------12/20--------------------------------------------------------------------------------
4.2
Change of the mode
There are 3 different modes that can be used:
Mode 1:
controlling via RS232/USB
Mode 2:
controlling via ARE i2
Mode 3:
controlling via digital inputs
The different modes affect just the controlling of the different channels. All other instructions are still
usable via the RS232/USB interface.
You have to use the instruction VSAVE after setting the mode, to save the changes permanently.
instruction:
MO <SP> 2
<CR>
answer:
2 <CR>
4.3
Changing the channel
The instruction to change the channel depends on the used mode. (see chapter 4.2)
Mode 1 (instruction on AMP) and mode 2 (instruction on i2):
instruction:
MP <SP> 1
<CR>
answer:
1 <CR>
The parameter 1..8 switches the channels 1..8 for the AMP 8 and the parameters 1..4 switch the
channels 1..4 of the AMP4. The parameter 0 switches all channels off.
Mode 3:
The controlling is binary via the states of the digital inputs.
4.4
Version
This instruction is used to get the firmware version of the AMP 4/8.
instruction:
VER <CR>
answer:
AEG ID AMP 4 V1.423<CR>
4.5
Initialiation with default parameters
This instruction sets back the parameters to default values.