25
ENGLISH
FIG. 17
FIG. 18
For butane/propane gas, the adjusting
screw must be tight screwed.
Make sure that the flame does not go
out passing quickly from the max. flow
to the minimum flow .
Assemble the knob again.
Z
We recommend that the cooker circuit is
rated to 13 amps.
Cable type HO5 RRF or HO5 RRF,
3 X 1.5 mm
2
.
This appliance must be installed
by a qualified person in
accordance with the latest edition
of the IEE Regulations and in
compliance with the manufactu-
rer instructions. Ensure that the
voltage is the same as that stated
on the rating plate.
If an fixed appliance is not equipped with
supply cable and plug, the power supply
Warning !
This appliance must be earthed
Connecting the mains cable
Open the mains terminal block cover as
shown, unscrew screw A the cable
Electrical connections
Burner
Natural Gas
G20 (2H) - 20 mbar
LPG (Butane/Propane)
G30/G31 - 28-30/37
kW
ini. 1/100
mm
m³/h
mm
ini. 1/100
g/h
Rapid
burner
Semirapid
burner
Auxiliary
burner
3,0
1,75
1,0
0,75
0,48
0,33
115
97
72
0,286
0,167
0,095
85
65
50
55
35
24
Triple crown
burner
3,3
1,30
130
0,343
96
95
Power kW
kW
Table D gas burner
must be fitted with a disconnect switch
in which the distance between contacts
permits total disconnection in accordance
with overvoltage category III, as required
by installation regulations.
Be sure that the earth wire green/yellow
is not interrupted by the switch
Содержание 47009GO-MN
Страница 1: ...47009GO MN EN COOKER USER MANUAL ...
Страница 28: ...538751 062011 www aeg electrolux com shop ...