Malfunctioning of cooler air temperature sensor
If during the normal operation a failure occurs to the cooler NTC temperature sensor (the signal coming from
the sensor is out of range), then:
When the sensor operates again normally, the above described conditions terminate.
Characteristics of the NTC sensor:
•
The display shows cooler temperature sensor faulty.
•
The air flow regulator (damper) operates as follows:
-
open when the compressor is on
-
closed when the compressor is off.
•
The defrosting procedure is activated every about 10 hours.