5.4.3
Cold module fan
The fan is located behind the cold module.
The air is intaken by the fan, therefore, in case of its replacement, ensure that the air is forced towards the cell
bottom.
The fan has the following characteristics:
-
voltage 240 V
-
power 3,1 W
-
speed 2000 rpm
5.4.4
Defrosting heater
The defrosting heater is used to defrost the ice that has accumulated on the battery evaporator.
The balancing heater has the following values:
-
power 240 W
-
voltage 240 V
-
resistance 240 Ohm
The fan stops in case of opening of the freezer door or of the cooler door.
To simulate the door closed, use a magnet and put it next to the magnetic sensor
located on the electronic board or push the freezer door button.