- ITZAA
32/44
599 38 47-44
6.9
Malfunctioning of freezer temperature sensor
If during the normal operation a failure occurs to the freezer NTC temperature sensor (the signal coming from
the sensor is out of range), then:
Characteristics of the NTC sensor:
•
The display shows freezer temperature sensor faulty.
•
The appliance operates with preset cycle when the compressor is powered for 40 minutes and
remains off for 40 minutes alternatively.
•
The defrosting procedure is activated every about 10 hours.
Содержание ENB 35400 X
Страница 3: ...ITZAA 3 44 599 38 47 44 10 DISPLAY SYMBOLS 43 10 1 Cooler compartment 43 10 2 Freezer compartment 44...
Страница 4: ...ITZAA 4 44 599 38 47 44...
Страница 9: ...ITZAA 9 44 599 38 47 44 4 ELECTRIC WIRING Check the specific diagram for each model...
Страница 15: ...ITZAA 15 44 599 38 47 44 1 free 2 free 3 free 4 free 1 free 2 free 3 freezer door switch 4 freezer door switch...
Страница 39: ...ITZAA 39 44 599 38 47 44 e View of the electronic board connectors...