- ITZAA
29/44
599 38 47-44
6.4
Flow chart for the defrosting management
START
More than 5 h elapsed after power on &
compressor off or compressor on for more
than 2,5 h?
no
yes
DEFROSTING
Resetting door accumulated timer
no
More than 14 h elapsed after
the last defrosting?
SUPER function activated?
no
yes
yes
More than 14 h elapsed after the last
defrosting & cooler or freezer door is open
from more than 6 minutes?
DEFROSTING
yes
no
More than 14 h elapsed after the last
defrosting & comp on for more than 2,5 h?
yes
no
More than 30 h elapsed after the last
defrosting & cooler or freezer door is open
from more than 1 minute?
yes
no
More than 72 h elapsed after the last
defrosting?
no
yes
DEFROSTING