If the system loses power the relay state is restored when the power is reconnected! 
 

3.8 

Exit Switch Enable 

 
The INPUTA  connection  can  be used  to activate  the output relay which is ideal  for  con-
nection to a secure-side exit switch.  It uses the trigger level for the input text message (see 
INLVL) and activates the relay as per a phone call.  To enable the exit switch input the EXIT 
command is sent to the board as follows: 
 

EXIT ENABLE

 

 

enables the exit switch input 

Exit disable

 

 

disable the exit switch input 

 

3.9 

Output Change Acknowledge SMS 

 
Where  necessary  the board  can  send  an  acknowledgement  SMS  text  message  to  all  of 
the TEXTNUM numbers showing the current status of the output.  When the output is actu-
ated by a telephone call or text message the activating number is also sent.  When the 
output  is  activated  via  an  exit  switch  (see  section  3.8)  on  INPUTA  the  relay  status  and 
‘MANUAL’ message is sent.  To activate and de-activate the acknowledge message the 
following command is sent to the board: 
 

Acknowledge Enable

  

enables the acknowledge text 

ACKNOWLEDGE DISABLE

 

disables the acknowledge text 

 

also valid, 
 

ack e

   

 

 

acknowledge enable 

ack d 

 

 

 

acknowledge disable 

 
 

4.1 

Auto-dialler:  Input Triggered SMS Text Message Sending and Autodialing 

 
The inputs can be used to trigger the sending of customisable SMS text messages to all of 
the ‘text numbers’ (see section 

1.3 Number Types

) and to sequentially dial all of the ‘call 

numbers’ (see section 

1.3 Number Types

). 

Call numbers are given priority and are dialled before the sending of SMS text messages 
to the Text Numbers.  If no call numbers are stored no call dialling will occur and the sys-
tem will begin sending SMS text messages straight away. 
Each input can be configured to either send  a text message, initiate dialling or both send 
a  text  message  and  dial  the  call  numbers.    Each  input  can  also  be  disabled  by  SMS  re-
motely. 
Each input has it’s own customisable message (see section 4.3) which can be sent when 
the associated input is triggered. 
Dialling can be triggered by either input in a logical OR configuration or can be triggered 
only when both inputs are active in a logical AND arrangement (see section 4.4).   Addi-
tionally, dialling can be triggered only when input A is triggered followed by input B in an 
A THEN B sequence. 
Calls are dialled in the order in which they are added.  The numbers are dialled sequen-
tially until a call is answered and rejected (hung-up) or a call is answered and the # key is 
pressed or until all of the numbers have been dialled. 
If a call is answered the system will automatically hang up the call after 5s.  The board will 
then call the next number.  During the 5s call the recipient can end dialling by holding the 
# key on their phone or by ending the call if the recipient is a mobile phone  After dialling 
is complete, the system will proceed to send the customisable text message to the list of 
text numbers. 

Содержание A3.02

Страница 1: ...QUAD Band GSM Relay Board and Auto Dialler A3 02 Firmware 3 20 Open on Call Access Control with Text Alert Auto Dial for GSM850MHz GSM900MHz DCS1800MHz PCS1900MHz www adventcontrols co uk ...

Страница 2: ...n 5 2 2 Command Message Format 5 2 3 Master Number Setup 5 2 4 Allowing Master Control for All Users 6 2 5 Adding a User Number 6 2 6 Removing a User Number 6 2 7 Viewing the Valid Number List 7 2 8 Finding a Number in the Memory 8 2 9 Clearing All Numbers and Settings 8 2 10 Result Acknowledgement Message 8 3 Relay Operation Access Control 8 3 1 Enabling Any Number and Disabling Open on Call 8 3 ...

Страница 3: ...RES by SMS text message SIM card balance checking can also be achieved using the SMS and Ser vice data forwarding functions The output relay has both Normally Open NO and Normally Closed NC with Common COM connections The action of the relay can be a single timed actuation from either 1s to 999s or 1 to 999 minutes or the relay can be set to toggle between calls 1 2 Technical Specification Power S...

Страница 4: ... is answered and the key is pressed See Section 4 1 Auto Dialler for details Example Call Number setup command Callnum 07000000000 Data Numbers Data Numbers are setup in a similar way to master numbers and allow settings to be amended using software A call from a data number may leave the unit unresponsive for up to 3 minutes after the call has ended Data numbers cannot activate the output relay D...

Страница 5: ...er the action as some mobile phones can enter superfluous characters at the end of a message which can invalidate the message The message is not cAsE sensitive 2 3 Master Number Setup The system is controlled by the master GSM mobile phone numbers see 2 2 Number Types The system must first be associated with at least one master phone s number before it can be used To do this the supplied 2 54mm ju...

Страница 6: ...efault MUSER is set to disable full access for all users N B Only master numbers can add other master numbers despite this setting 2 5 Adding a User Number Any telephone number of at least 5 digits where caller ID is available is valid The system only compares the last 8 digits if present of any calling number against the numbers stored in memory Therefore it is not necessary to enter the internat...

Страница 7: ...a SMS text message containing a complete list of valid user numbers to any master phone To receive the list of numbers the LIST command is used The master phone must send the following SMS text message to the system List The response format shows the number type the channel if applicable and the last 8 digits of the stored number followed by a space and the next number and so on Number Types T Tex...

Страница 8: ...ommand This does not affect the customisable input text messages 2 10 Result Acknowledgement Message The system can be setup to send a SMS text message to acknowledge a command This acknowledges the result of the last command processed such as adding a new user number The SIM card in the system must have sufficient credit for sending SMS text mes sages To enable disable the service the following t...

Страница 9: ...e call is deactivating the relay connects the call when the call is activating the relay REJECT NONE disables all call rejection 3 3 Connecting a Call By default when called the system is set to ring indefinitely or until the SIM card network operator transfers the call to voicemail However the system can be set to connect a call when the input is OPen high 12V or Closed low 0V This is done to all...

Страница 10: ...ion time Rlytime 1m 1 minute activation time RLYTIME 960m 16 hour 16 x 60mins activation time 3 7 OPEN ON CLOSE OFF Commands The OPEN and ON commands are used to activate the relay with a SMS text message The CLOSE and OFF commands deactivate the relay whether activated by the OPEN or ON command or a call When the OPEN command is sent without any additional instruc tions the relay is activated ind...

Страница 11: ...rs see section 1 3 Number Types and to sequentially dial all of the call numbers see section 1 3 Number Types Call numbers are given priority and are dialled before the sending of SMS text messages to the Text Numbers If no call numbers are stored no call dialling will occur and the sys tem will begin sending SMS text messages straight away Each input can be configured to either send a text messag...

Страница 12: ...nput A is the default input if not specified inpb b INPB D 4 2 Input Change State Level The INLEVEL sets the active state of the input for triggering the auto dialler For example if the user requires triggering when the input is going closed GND then the following message is sent by the master number INLEVEL CLOSED trigger when input A closed GND If the trigger is required when the input goes open...

Страница 13: ...te dialling AND configuration Additionally the system can be set for input A to be triggered before input B A THEN B in order to initiate dialling To change the autodial logic settings the following message is sent to the board autodial AND requires both inputs to be active to initiate dialling autodial OR triggering either input initiates dialling AUTODIAL THEN A THEN B triggering aut A aut o Aut...

Страница 14: ...B Text Call numbers can also activate the output there is no need to ADD the number 4 11 International Calling Texting The system can call text international numbers however the exit code should not be specified and should be replaced with the symbol e g UK Number 07574163367 should be entered as 447574163367 when outside the UK 4 12 Dial Now If necessary the system can make a call to a number not...

Страница 15: ...ow ing SMS text message is sent to the system KAT space number frequency enables periodic text message sending e g KAT 07000000000 10 text 07000000000 every 10 days KAT Off disables periodic text message sending Frequency number of days interval The default setting for the Keep Alive Call KAC are a call to 441512834306 every 56 days This can be changed using the KAC command KAC 441512834306 50 dia...

Страница 16: ...all unsolicited messages from unrecognised numbers i e not user or master num bers to the forwarding phone number However to stop excessive spamming and wasting credit the service can be enabled in temporary mode limiting to forwarding messages for only 3 minutes after a master user has sent a valid message typically the SMS or DIAL command Additionally only one message will be forwarded every min...

Страница 17: ...terminals If DC supply voltages are liable to drop below 12VDC or it is mandatory that the GND termi nal be at the same voltage level as the supply ground connect the negative 0v supply to the GND terminal and the supply ve to the outer most VIN terminal terminal number 5 This will bypass the bridge rectifier for the GND negative supply Please note if using this equipment in a motor vehicle please...

Страница 18: ...t most alarms pull the negative terminal down to ground when active the installer should ensure this is the case with their alarm system If the alarm output goes from GND to VE or open circuit the INLEVEL settings must be changed see section 4 3 Alternatively it may be necessary to use an intermediate relay board for connection to some systems Please contact sup port adventcontrols co uk for assis...

Страница 19: ...nector It is not recommended to use an extension greater than 3m in length 6 6 Mounting The PCB has been designed to fit into a Hammond 1591B enclosure When mounting the unit into such an enclosure the enclosure must be modified to allow for the antenna coaxial cable to be connected When mounting in a metal cabinet an external an tenna must be used connected using 50ohm impedance coaxial cable If ...

Страница 20: ...PUTX DISABLE INLEVELX CLOSE OPEN BOTH Input Edge 4 2 KA number frequency Keep Alive Message LIST List All Numbers MASTER number Add Master User MUSER DISABLE ENABLE Treat all users as Master OFF as CLOSE Deactivate Relay OPEN ON minutes m Activate Relay with Time PSMS ENABLE DISABLE Power Up Text Alert QUERY QNUM number Find Number in Memory REJECT ALL NEVER OPEN Call Handling REMOVE C D M T numbe...

Отзывы: