background image

The result LED, LED2, will flash two times to indicate the master number has been success-
fully  setup.    Calling  the  board’s  telephone  number  with  the  master  phone  will  now  acti-
vate the relay.  Once one master number has been setup further masters (up to 512) can 
be setup by this and subsequent master phones without the jumper fitted (using the same 
message). 

 
Using the PIN for Master Setup 

 
The Master Number can also be set up using the PIN.  This is only possible for the first master 
number  that  is  added  to  the  system.    Subsequent  masters  must  be  added  by  a  master 
using the MASTER command.  The PIN is the last 5 characters of the IMEI number written on 
the QUECTEL GSM module sticker.  The command is sent as follows: 
 

Master 07000000000,37212. 

 

for module with IMEI 3550730342

37212 

 
 
2.4  Allowing Master Control for all Users 

 
To enable any user to control master commands (such as adding and removing numbers) 
the MUSER command is sent to the board, by a master number, as follows: 
 

MUSER

 ENABLE 

 

Allows any valid user number to modify settings 

MUSER

 DISABLE 

 

Only master numbers can modify settings 

 
By  default MUSER is  set  to  disable  full access  for all users.  N.B.  Only master  numbers  can 
add other master numbers despite this setting 

 
 
2.5 

Adding a User Number 

 
Any telephone number of at least 5 digits where caller ID is available is valid.  The system 
only  compares  the  last  8  digits  (if  present)  of  any  calling  number  against  the  numbers 
stored  in  memory.    Therefore  it  is  not  necessary  to  enter  the  international  dialling  code 
format of the telephone number. 
 
i.e. for 070

00000000 

only the characters shown in 

BOLD

 text are considered 

 
The ADD command is used to add a new telephone number.  To add a new number any 
master phone must send the following SMS text message to the system telephone number: 
 

add

<space>

number

.    e.g. 

Add 07000000000.

 

 
If TEXTRES is enabled the system will respond with the ‘Operation Successful’ message. 
 

2.6 

Removing a User Number 

 
The REMOVE command is used to remove an existing telephone number.  To remove an 
existing telephone number any master phone must send the following SMS text message: 
 

remove

<space>

number

.    e.g. 

REMOVE 07000000000. 

 

The REMOVE command must be sent for each number in the memory.  The user can spec-
ify which  number  type  is  desired  to  be  removed  and  only  that  type  will  be  removed  re-
gardless of whether the number is already in the memory in a different form. 

Содержание A3.02

Страница 1: ...QUAD Band GSM Relay Board and Auto Dialler A3 02 Firmware 3 20 Open on Call Access Control with Text Alert Auto Dial for GSM850MHz GSM900MHz DCS1800MHz PCS1900MHz www adventcontrols co uk ...

Страница 2: ...n 5 2 2 Command Message Format 5 2 3 Master Number Setup 5 2 4 Allowing Master Control for All Users 6 2 5 Adding a User Number 6 2 6 Removing a User Number 6 2 7 Viewing the Valid Number List 7 2 8 Finding a Number in the Memory 8 2 9 Clearing All Numbers and Settings 8 2 10 Result Acknowledgement Message 8 3 Relay Operation Access Control 8 3 1 Enabling Any Number and Disabling Open on Call 8 3 ...

Страница 3: ...RES by SMS text message SIM card balance checking can also be achieved using the SMS and Ser vice data forwarding functions The output relay has both Normally Open NO and Normally Closed NC with Common COM connections The action of the relay can be a single timed actuation from either 1s to 999s or 1 to 999 minutes or the relay can be set to toggle between calls 1 2 Technical Specification Power S...

Страница 4: ... is answered and the key is pressed See Section 4 1 Auto Dialler for details Example Call Number setup command Callnum 07000000000 Data Numbers Data Numbers are setup in a similar way to master numbers and allow settings to be amended using software A call from a data number may leave the unit unresponsive for up to 3 minutes after the call has ended Data numbers cannot activate the output relay D...

Страница 5: ...er the action as some mobile phones can enter superfluous characters at the end of a message which can invalidate the message The message is not cAsE sensitive 2 3 Master Number Setup The system is controlled by the master GSM mobile phone numbers see 2 2 Number Types The system must first be associated with at least one master phone s number before it can be used To do this the supplied 2 54mm ju...

Страница 6: ...efault MUSER is set to disable full access for all users N B Only master numbers can add other master numbers despite this setting 2 5 Adding a User Number Any telephone number of at least 5 digits where caller ID is available is valid The system only compares the last 8 digits if present of any calling number against the numbers stored in memory Therefore it is not necessary to enter the internat...

Страница 7: ...a SMS text message containing a complete list of valid user numbers to any master phone To receive the list of numbers the LIST command is used The master phone must send the following SMS text message to the system List The response format shows the number type the channel if applicable and the last 8 digits of the stored number followed by a space and the next number and so on Number Types T Tex...

Страница 8: ...ommand This does not affect the customisable input text messages 2 10 Result Acknowledgement Message The system can be setup to send a SMS text message to acknowledge a command This acknowledges the result of the last command processed such as adding a new user number The SIM card in the system must have sufficient credit for sending SMS text mes sages To enable disable the service the following t...

Страница 9: ...e call is deactivating the relay connects the call when the call is activating the relay REJECT NONE disables all call rejection 3 3 Connecting a Call By default when called the system is set to ring indefinitely or until the SIM card network operator transfers the call to voicemail However the system can be set to connect a call when the input is OPen high 12V or Closed low 0V This is done to all...

Страница 10: ...ion time Rlytime 1m 1 minute activation time RLYTIME 960m 16 hour 16 x 60mins activation time 3 7 OPEN ON CLOSE OFF Commands The OPEN and ON commands are used to activate the relay with a SMS text message The CLOSE and OFF commands deactivate the relay whether activated by the OPEN or ON command or a call When the OPEN command is sent without any additional instruc tions the relay is activated ind...

Страница 11: ...rs see section 1 3 Number Types and to sequentially dial all of the call numbers see section 1 3 Number Types Call numbers are given priority and are dialled before the sending of SMS text messages to the Text Numbers If no call numbers are stored no call dialling will occur and the sys tem will begin sending SMS text messages straight away Each input can be configured to either send a text messag...

Страница 12: ...nput A is the default input if not specified inpb b INPB D 4 2 Input Change State Level The INLEVEL sets the active state of the input for triggering the auto dialler For example if the user requires triggering when the input is going closed GND then the following message is sent by the master number INLEVEL CLOSED trigger when input A closed GND If the trigger is required when the input goes open...

Страница 13: ...te dialling AND configuration Additionally the system can be set for input A to be triggered before input B A THEN B in order to initiate dialling To change the autodial logic settings the following message is sent to the board autodial AND requires both inputs to be active to initiate dialling autodial OR triggering either input initiates dialling AUTODIAL THEN A THEN B triggering aut A aut o Aut...

Страница 14: ...B Text Call numbers can also activate the output there is no need to ADD the number 4 11 International Calling Texting The system can call text international numbers however the exit code should not be specified and should be replaced with the symbol e g UK Number 07574163367 should be entered as 447574163367 when outside the UK 4 12 Dial Now If necessary the system can make a call to a number not...

Страница 15: ...ow ing SMS text message is sent to the system KAT space number frequency enables periodic text message sending e g KAT 07000000000 10 text 07000000000 every 10 days KAT Off disables periodic text message sending Frequency number of days interval The default setting for the Keep Alive Call KAC are a call to 441512834306 every 56 days This can be changed using the KAC command KAC 441512834306 50 dia...

Страница 16: ...all unsolicited messages from unrecognised numbers i e not user or master num bers to the forwarding phone number However to stop excessive spamming and wasting credit the service can be enabled in temporary mode limiting to forwarding messages for only 3 minutes after a master user has sent a valid message typically the SMS or DIAL command Additionally only one message will be forwarded every min...

Страница 17: ...terminals If DC supply voltages are liable to drop below 12VDC or it is mandatory that the GND termi nal be at the same voltage level as the supply ground connect the negative 0v supply to the GND terminal and the supply ve to the outer most VIN terminal terminal number 5 This will bypass the bridge rectifier for the GND negative supply Please note if using this equipment in a motor vehicle please...

Страница 18: ...t most alarms pull the negative terminal down to ground when active the installer should ensure this is the case with their alarm system If the alarm output goes from GND to VE or open circuit the INLEVEL settings must be changed see section 4 3 Alternatively it may be necessary to use an intermediate relay board for connection to some systems Please contact sup port adventcontrols co uk for assis...

Страница 19: ...nector It is not recommended to use an extension greater than 3m in length 6 6 Mounting The PCB has been designed to fit into a Hammond 1591B enclosure When mounting the unit into such an enclosure the enclosure must be modified to allow for the antenna coaxial cable to be connected When mounting in a metal cabinet an external an tenna must be used connected using 50ohm impedance coaxial cable If ...

Страница 20: ...PUTX DISABLE INLEVELX CLOSE OPEN BOTH Input Edge 4 2 KA number frequency Keep Alive Message LIST List All Numbers MASTER number Add Master User MUSER DISABLE ENABLE Treat all users as Master OFF as CLOSE Deactivate Relay OPEN ON minutes m Activate Relay with Time PSMS ENABLE DISABLE Power Up Text Alert QUERY QNUM number Find Number in Memory REJECT ALL NEVER OPEN Call Handling REMOVE C D M T numbe...