APAX-5000 I/O Series User Manual
78
A/B Phase 4X, With Reload, Count Once
Figure 3.20 shows A/B Phase 4X mode, Ch0_A and Ch0_B provide the counting
function. When the counter0 is enabled, the couner0 starts to count. If the counter
value is overflow or underflow, it will reset to the defined value (e.g. 0x33) and keep
counting repetitively.
Figure 3.34 A/B Phase 4X, With Reload, Count Once
0x33
0x33
Ch0_A
Ch0_B
Counter 0
Value
Counter 0
Enable
0x32 0x31 0x30
0x2F
0x30 0x31 0x32 0x33 0x34 0x35
……
0xF ..F
Counter0
Overflow
Ch0_A
Ch0_B
Counter 0
Value
Counter 0
Enable
0x33
0x33
0x34 0x35 0x36
0x37
0x36 0x35 0x34 0x33 0x32 0x31
……
0x00
Counter0
Underflow