Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 37 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
10.7 TEST RESULT
Date of Test
May 23, 2005
Temperature
23
℃
Test Mode
Mode 1
Humidity
65 %
Inject Line
Voltage
KV
Repetition
Rate
(minute)
Phase
Angle
Surge
applied
Method
Number
of tests
Required
Criteria
Complied
to Criteria
Result
1 0
°
Coupling
5 B A
PASS
1 90
°
Coupling
5 B A
PASS
1 180
°
Coupling
5 B A
PASS
+0.5
+1.0
1 270
°
Coupling
5 B A
PASS
1 0
°
Coupling
5 B A
PASS
1 90
°
Coupling
5 B A
PASS
1 180
°
Coupling
5 B A
PASS
L-N
Differential
mode
-0.5
-1.0
1 270
°
Coupling
5 B A
PASS
1 0
°
Coupling
5 B A
PASS
1 90
°
Coupling
5 B A
PASS
1 180
°
Coupling
5 B A
PASS
+0.5
+1.0
+2.0
1 270
°
Coupling
5 B A
PASS
1 0
°
Coupling
5 B A
PASS
1 90
°
Coupling
5 B A
PASS
1 180
°
Coupling
5 B A
PASS
L-PE
Common
mode
-0.5
-1.0
-2.0
1 270
°
Coupling
5 B A
PASS
1 0
°
Coupling
5 B A
PASS
1 90
°
Coupling
5 B A
PASS
1 180
°
Coupling
5 B A
PASS
+0.5
+1.0
+2.0
1 270
°
Coupling
5 B A
PASS
1 0
°
Coupling
5 B A
PASS
1 90
°
Coupling
5 B A
PASS
1 180
°
Coupling
5 B A
PASS
N-PE
Common
mode
-0.5
-1.0
-2.0
1 270
°
Coupling
5 B A
PASS
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
There was no observable degradation in performance.
EUT stopped operation and could / could not be reset by operator at V/m at
frequency
MHz.
No false alarms or other malfunctions were observed during or after the test. The
acceptance criteria were met, and the EUT passed the test.