Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 28 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
7.7 TEST RESULT
Date of Test
May 24, 2005
Temperature
20
℃
Test Mode
Mode 1
Humidity
55 %
Item
Amount of
Discharge
Voltage
Required
Criteria
Complied
to Criteria
(A, B, C)
Result
10
+2kV
+4kV
+8kV
+15kV
B A
PASS
Air
Direct
Discharge
10
-
2kV
-
4kV
-
8kV
-
15kV
B A
PASS
25
+
2kV
+4kV
+6kV
+8kV
B B
PASS
Contact
Direct
Discharge
25
-2kV
-4kV
-6kV
-8kV
B B
PASS
25
+
2kV
+4kV
+6kV
+8kV
B A
PASS
Indirect
Discharge
(HCP)
25
-2kV
-4kV
-6kV
-8kV
B A
PASS
25
+
2kV
+4kV
+6kV
+8kV
B A
PASS
Indirect
Discharge
(VCP)
(Front)
25
-2kV
-4kV
-6kV
-8kV
B A
PASS
25
+
2kV
+4kV
+6kV
+8kV
B A
PASS
Indirect
Discharge
(VCP)
(Left)
25
-2kV
-4kV
-6kV
-8kV
B A
PASS
25
+
2kV
+4kV
+6kV
+8kV
B A
PASS
Indirect
Discharge
(VCP)
(Back)
25
-2kV
-4kV
-6kV
-8kV
B A
PASS
25
+
2kV
+4kV
+6kV
+8kV
B A
PASS
Indirect
Discharge
(VCP)
(Right)
25
-2kV
-4kV
-6kV
-8kV
B A
PASS
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
There was no observable degradation in performance.
The LAN was slow response slightly.
No false alarms or other malfunctions were observed during or after the test.
The acceptance criteria were met, and the EUT passed the test
★
The blue tag means the air discharge point .
★
The rad tag means the contact point .