Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 17 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
5.3.2 OPEN AREA TEST SITE & ANECHOIC CHAMBER SETUP DIAGRAM
Note: This is a reprehensive setup diagram for Table-top EUT.
For Floor-standing EUT, the table will be removed with all others setup condition remain the same.
5.4 RADIATED EMISSION LIMITS
Class B Limits
Frequency Distance Field
Strength
MHz Meter dB(µV/m)
30 to 230
10
30
230 to 1000
10
37
Class A Limits
Frequency Distance Field
Strength
MHz Meter dB(µV/m)
30 to 230
10
40
230 to 1000
10
47
Remark: 1. The tighter limit shall apply at the edge between two frequency bands.
2. Distance refers to the distance in meters between the measuring antenna and
the closest point of any part of the device or system.
EUT
FRP Dome
Test
Receiver
Antenna Mast
TO controller
To Receiver
Metal Full Soldered Ground Plane
Non-Condu
ctive Table
10m
1m to 4m
80cm
Broadband or
Dipole Antenna
Antenna height
can be moved
from 1m to 4m;
Antenna and
turntable distance
10m