8.7 TEST RESULT
Date of Test
May 24, 2005
Temperature
23
℃
Test Mode
Mode 1
Humidity
65 %
Freq. Range
(MHz)
Position
(Angle)
Polarity
(H or V)
Field Strength
(V/m)
Performance
Criteria
Complied to
Results
0
H / V
3
A
PASS
90
H / V
3
A
PASS
180
H / V
3
A
PASS
26-80 MHz
80-1000 MHz
900 ± 5 MHz
270
H / V
3
A
PASS
Additional comprehensive functional test selected frequencies are:
80, 120, 160, 230, 434, 460, 600, 863 and 900(+/- 1%)MHz.
Freq. Range
(MHz)
Position
(Angle)
Polarity
(H or V)
Field Strength
(V/m)
Performance
Criteria
Complied to
Results
80
0;90;180;270
H / V
3
A PASS
120
0;90;180;270
H / V
3
A
PASS
160
0;90;180;270
H / V
3
A
PASS
230
0;90;180;270
H / V
3
A PASS
434
0;90;180;270
H / V
3
A
PASS
460
0;90;180;270
H / V
3
A
PASS
600
0;90;180;270
H / V
3
A PASS
863
0;90;180;270
H / V
3
A
PASS
900
0;90;180;270
H / V
3
A
PASS
Meet criteria A: Operate as intended during and after the test
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
There was no observable degradation in performance.
EUT stopped operation and could / could not be reset by operator at V/m at
frequency
MHz.
No false alarms or other malfunctions were observed during or after the test. The
acceptance criteria were met, and the EUT passed the test.