background image

 

List of figures 

 
 

DLT-SA6100 Screen Blanking Solution, Manual V1.00 

 

 27 / 27 

11.  List of figures 

Figure 4.1: DLT-SA6100 Sensor Stick connected to ADLoG vehicle mounted terminal ........................................ 11

 

Figure 5.1: DLT-SA6100 Sensor Stick with USB plug cover ................................................................................. 13

 

Figure 6.1: Dimensions DLT-SA6100 Sensor Stick ............................................................................................... 14

 

Figure 7.1: Example ADLoG VMT: DLT-V83 with cable cover opened, 3 USB slots ............................................. 16

 

Figure 7.2: ADLoG Screen Blanking Setup – Welcome screen ............................................................................. 17

 

Figure 7.3: ADLoG Screen Blanking Setup – Start menu folder ............................................................................ 18

 

Figure 7.4: ADLoG Screen Blanking Setup – Confirm installation location ............................................................ 19

 

Figure 7.5: ADLoG Screen Blanking Setup completed .......................................................................................... 20

 

Figure 7.6: ADLoG Screen Blanking Setup finished .............................................................................................. 20

 

Figure 7.7: ADLoG Screen Blanking Config Tool .................................................................................................. 21

 

 

 
 

Содержание DLT-SA6100

Страница 1: ...DLT SA6100 Screen Blanking Solution User Manual V1 00 EN User Manual ...

Страница 2: ...dvantech Co Ltd assumes no liability for technical inaccuracies typographic errors or faults in this documentation Advantech Co Ltd also assumes no liability for damages caused directly or indirectly by the delivery performance or usage of this material Note regarding all links and website content included in this document Advantech Co Ltd is not responsible for the accessibility of the websites a...

Страница 3: ...vehicle mounted terminals 11 4 2 2 Operating systems supported 12 4 3 Mount operate and service the device correctly 12 5 PACKING LIST 13 6 TECHNICAL DATA DLT SA6100 SENSOR STICK 14 7 INITIAL START UP 15 7 1 Connect the DLT SA6100 Sensor Stick 15 7 1 1 Notes for ADLoG vehicle mounted terminals 16 7 2 Download DLT SA6100 Screen Blanking Solution software 16 7 3 Install DLT SA6100 Screen Blanking So...

Страница 4: ...de and Safety Notes First steps in commissioning Skilled personnel Printed included with the device User Manual Complete operating instructions Skilled personnel PDF file at our websites 1 2 Latest manual versions The latest versions of our manuals are available at our websites www advantech com www advantech service iot eu 1 3 DLT SA6100 Screen Blanking Solution version described This manual desc...

Страница 5: ...ury will occur if this information is not observed WARNING means that death or severe bodily injury can occur if this information is not observed CAUTION means that slight bodily injury can occur if this information is not observed NOTICE Possible system malfuntion Information about possible system malfunction and property damage TIP NOTE Tips notes about how to handle or use the product Note abou...

Страница 6: ...ter for technical support Please have the following information ready Product name Serial number Description of your peripheral attachments Description of your software operating system application software etc The exact wording of any error messages A complete description of the problem Find the contact data of our Global Advantech Service Centers on website http erma advantech com ...

Страница 7: ...DLT SA6100 Screen Blanking Solution must be instructed by skilled personnel In ongoing operation In the event of malfunctions of the DLT SA6100 Screen Blanking Solution the driver is not permitted to be distracted by the screen display Never unplug the DLT SA6100 Sensor Stick during travel do not delete modify or close the associated software application otherwise the screen blanking will no longe...

Страница 8: ... the DLT SA6100 Sensor Stick against unauthorized removal Use a USB port that is hard to access during work This means that the DLT SA6100 Sensor Stick is optimally protected against accidental unplugging 3 2 4 Notes for ADLoG vehicle mounted terminals Connect the DLT SA6100 Sensor Stick to a USB port underneath the cable cover of the ADLoG vehicle mounted terminal Do not use the service USB port ...

Страница 9: ...nking on each vehicle mounted terminal in the actual usage environment Re configure the system as necessary and re test 3 4 Service the system on a regular basis Vehicle mounted terminals are subjected to high loads due to vibration and shocks The DLT SA6100 Sensor Stick is designed especially for this usage However the DLT SA6100 Sensor Stick may loosen in some circumstances meaning functionality...

Страница 10: ...n Blanking Solution system shall be solely liable for any damage resulting from improper use This also applies to unauthorized modifications made to the system DLT SA6100 Screen Blanking Solution is permitted to be used on the company site but not on public streets and in public locations For DLT SA6100 Screen Blanking Solution the corresponding defined Intended use of the vehicle mounted terminal...

Страница 11: ...hicle mounted terminals DLT V72 Series DLT V83 Series DLT V6210 DLT V4108 DLT M8110 Docking Station The DLT SA6100 Sensor Stick has been connected in each case for the tests to a USB port underneath the cable cover on the ADLoG vehicle mounted terminal These USB ports fulfill the following technical requirements USB 2 0 port type A Vibration proof tested for resistance to vibration High retention ...

Страница 12: ... the device correctly DLT SA6100 Screen Blanking Solution was designed and built according to modern technology and accepted safety regulations However the operation of the DLT SA6100 Screen Blanking Solution can endanger personnel or third parties and cause damage to the device and other material assets when for example the device is installed incorrectly or configured improperly operated by untr...

Страница 13: ...stem check that the item listed below is included and in good condition If the item does not accord with the table please contact your dealer immediately DLT SA6100 Screen Blanking Solution Quick Start Guide including Safety Notes DLT SA6100 Sensor Stick Figure 5 1 DLT SA6100 Sensor Stick with USB plug cover ...

Страница 14: ...T SA6100 Screen Blanking Solution Manual V1 00 6 Technical data DLT SA6100 Sensor Stick Operating temperature 40 C to 80 C 40 F to 176 F USB type 2 0 Power consumption rating 5 V 0 25 A Dimensions in mm Figure 6 1 Dimensions DLT SA6100 Sensor Stick ...

Страница 15: ...ctionality is no longer guaranteed Use a USB port that is hard to access during work This means that the DLT SA6100 Sensor Stick is optimally protected against accidental unplugging Ensure that the DLT SA6100 Sensor Stick is securely plugged into the USB port at all times WARNING Risk of accident because the DLT SA6100 Sensor Stick is loose during ongoing operation or the stick is unplugged For DL...

Страница 16: ...er guaranteed To access the USB ports underneath the cable cover this cable cover on the vehicle mounted terminal must be opened and closed correctly Please note the following Work on the ADLoG vehicle mounted terminal is only permitted to be performed by adequately qualified skilled personnel Follow the instructions in the relevant ADLoG vehicle mounted terminal manual Figure 7 1 Example ADLoG VM...

Страница 17: ...on different operating systems The DLT SA6100 Screen Blanking Solution software is installed with menu guidance and provides the user with identical dialogs in all available operating systems Only WinEmbStd7 will display an additional Windows Security checkbox that must be accepted 7 3 2 Start installation Before you start software installation Please check if DLT SA6100 Sensor Stick is properly i...

Страница 18: ... ADLoG Screen Blanking Setup Start menu folder Confirm with Install The installation directory is then specified NOTICE Possible system malfuntion The suggested installation directory C Program Files ADLoG ScreenBlanking must be used to ensure correct functionality Accept the suggested installation location ...

Страница 19: ...Initial start up DLT SA6100 Screen Blanking Solution Manual V1 00 19 27 Figure 7 4 ADLoG Screen Blanking Setup Confirm installation location Confirm with Next ...

Страница 20: ...ation progress is displayed in an info dialog Figure 7 5 ADLoG Screen Blanking Setup completed Click on Next Select check box Start ADLoG Screen Blanking Configuration Tool to immediately open the configuration dialog Confirm with Finish Figure 7 6 ADLoG Screen Blanking Setup finished ...

Страница 21: ...n Blanking Config Tool can be started manually 7 5 Configuration 7 5 1 Vehicle mounted terminal specific modification required DLT SA6100 Screen Blanking Solution must be configured specifically for each vehicle mounted terminal as the automatic screen blanking depends on the vehicle type and the conditions of use of the vehicle for example If no vehicle mounted terminal specific configuration is ...

Страница 22: ...t Where is the vehicle mounted terminal fitted on the vehicle The vibrations vary depending on the mounting location console under the roof etc What has been used to mount the vehicle mounted terminal to the vehicle The vibrations vary depending on the mounting type long or short RAM mounts ADLoG mounting bracket etc The Sensitivity level that needs to be set for the vehicle mounted terminal depen...

Страница 23: ...timally filled A frame is only left clear for the optional display of the time Show time This setting specifies whether or not the current time is to be shown on the blanked display The time format corresponds to the MS Windows country settings for the ADLoG vehicle mounted terminal in question Example for USA hh mm ss AM PM 7 6 Roll out across multiple terminals A configuration created and stored...

Страница 24: ... terminal in the actual usage environment WARNING Risk of accident as the DLT SA6100 Screen Blanking Solution configuration is not functioning in the usage environment If the configuration carried out is not appropriate for the usage environment the blanking function cannot be guaranteed and the driver may be distracted Test the blanking function in the actual usage environment before putting it i...

Страница 25: ...are subjected to high loads due to vibration and shocks The DLT SA6100 Sensor Stick is designed especially for this usage However the DLT SA6100 Sensor Stick may loosen in some circumstances meaning functionality may be restricted WARNING Risk of accident if the DLT SA6100 Sensor Stick becomes loose during ongoing operation If the DLT SA6100 Sensor Stick becomes loose the sensors will no longer de...

Страница 26: ...isposed of as normal waste DLT SA6100 Sensor Sticks that are no longer being used may not be disposed of in the regular residential or domestic waste they must be taken to an official public collection point and handled by a disposal provider Please contact the responsible authorities in your country region to find out about the applicable regulations for proper disposal if necessary ...

Страница 27: ...sions DLT SA6100 Sensor Stick 14 Figure 7 1 Example ADLoG VMT DLT V83 with cable cover opened 3 USB slots 16 Figure 7 2 ADLoG Screen Blanking Setup Welcome screen 17 Figure 7 3 ADLoG Screen Blanking Setup Start menu folder 18 Figure 7 4 ADLoG Screen Blanking Setup Confirm installation location 19 Figure 7 5 ADLoG Screen Blanking Setup completed 20 Figure 7 6 ADLoG Screen Blanking Setup finished 20...

Отзывы: