background image

 

 

www.advancedco.com 

 

 

 

 

Advanced Electronics Ltd 
Moorland Way, Cramlington, Northumberland, NE23 1WE   UK 

Tel:

 +44 (0)1670 707 111   

Fax:

 +44 (0)1670 707 222 

Email:

 [email protected] 

Web:

 www.advancedco.com 

Doc Number: 

680-133 

Revision: 

02A 

 

Содержание Mxp-035

Страница 1: ...output is fully programmable using the powerful DynamiX cause and effects rules and all outputs are synchronised The unit is available as either a printed circuit card only or as a boxed version with...

Страница 2: ...of the Mxp 031 Peripheral Bus Interface Adaptor card in the panel Item Specification Details Applicable Standards EN54 2 1997 BS EN54 4 1997 Operating Temperature 5 C to 40 C Relative Humidity 95 non...

Страница 3: ...6 2 6 WIRING 7 2 6 1 AC Wiring Boxed Units 7 2 6 2 Battery Installation Boxed Unit 7 2 6 3 DC Power and Serial Communications 8 2 6 4 Power Supply Fault Input 8 3 PROGRAMMING AND CONFIGURATION 9 3 1 A...

Страница 4: ...required When All Other Outputs are disabled at the panel all relay outputs attached to the panel are disabled Outputs can also be individually disabled via the user menus or disabled using the group...

Страница 5: ...ircuit card shall be fitted to a metal chassis or in a metal enclosure using the M3 spacers nuts and screws supplied The chassis enclosure must be connected to protective earth Refer to the diagram op...

Страница 6: ...commended routing of cables 2 4 PCB Mounting in a 5000 Panel There is provision on the 5000 chassis plate to mount one peripheral bus module except 5100 small enclosure Refer to panel manual 680 165 f...

Страница 7: ...contact with high frequency interference such as portable radio transceivers etc the data wiring cable should be of a twisted pair construction within a overall screen Care should be taken to correct...

Страница 8: ...or Jumper ON with termination Jumper OFF no termination Peripheral Bus 4 Way Relay Card TB1 A B A B TB2 OUT IN 24V 0V Fault TB7 4 Way Relay Card TB1 A B A B TB2 OUT IN 24V 0V Fault TB7 FIGURE 6 Critic...

Страница 9: ...e and click on the Mxp 035 option to highlight and select it The zone number is pre assigned to the zone number of the panel This can be changed if an alternative zone is required for these circuits S...

Страница 10: ...he button to delete the 4 way relay card from the address 3 3 Configuring the Output Circuits 3 3 1 Basic Details Click the button to show a list of the addresses and sub addresses for all of the devi...

Страница 11: ...group 0 Invert Output Determines if the output is normally OFF not inverted and activates on the event or normally ON inverted and de activates on the event No May Silence Determines if the output wil...

Страница 12: ...dco com Advanced Electronics Ltd Moorland Way Cramlington Northumberland NE23 1WE UK Tel 44 0 1670 707 111 Fax 44 0 1670 707 222 Email sales advancedco com Web www advancedco com Doc Number 680 133 Re...

Отзывы: