Power supply: backed up external 12 VDC
Consumption in standby mode: 0.1 mA / 12 V
Consumption in alarm mode: 35 mA / 12 V
Indoor environment
Operating temperature: - 10°C to +50°C
Number of relays per smoke detector alarm: unlimited
Range of radio link in free field: 100 m
Cut-off power: 1 A / 30 V
0 405 14
Radio relay
Safety instructions
This product should be installed in compliance with installation rules,
preferably by a qualified electrician. Incorrect installation and use can lead
to risk of electric shock or fire.
Before carrying out the installation, read the instructions and take account
of the product’s specific mounting location.
Do not open up, dismantle, alter or modify the device except where
specifically required to do so by the instructions. All Legrand products
must be opened and repaired exclusively by personnel trained and
approved by Legrand. Any unauthorised opening or repair completely
cancels all liabilities and the rights to replacement and guarantees.
Use only Legrand brand accessories.
Operation
:
The radio relay changes status
(NO/NC toggle contact) when an
alarm signal is sent from a smoke
detector alarm.
110
50
110
0 405 18
0 405 28
0 405 14
This product is governed by Directive 2002/96/EC - Waste Electrical and Electronic Equipment (WEEE).
This symbol, placed on the product or its packaging, indicates that the product must not be disposed of with
household waste. It must be taken to an appropriate collection centre for the recycling of electrical and
electronic equipment.
This product complies with Directive ROHS 2002/95/EC on limiting the use of certain hazardous substances
in WEEE since 1 July 2006.
R
Can be paired with smoke detector alarms
with radio link (Cat. No. 0 405 28)
Connection terminal
Assembly
12 VDC
backed up
Device to be
triggered
(alarm, ...)
Installation
Configuration
push button
BR1
BR2
BR3
-
Supply
+
-
input
+
C
Relay
NC NO
+
-
max 1,5mm²
BR1
BR2
BR3
-
Supply
+
-
input
+
C
Relay
NC NO
Power supply
12 Vdc
C
R
T
Local alarm
input
(N.O contact)
Relay contact
Environmental protection
LE05798AB_EN
Note:
- In TEST mode, the BR3 output relay is not activated.
- In ALARM mode, the BR3 output relay is activated.