High Efficiency - High Intensity
KMI_02142017al
MODEL
NO.
NOMINAL THERMAL LOAD
WEIGHT
(lbs)
NATURAL GAS
(btu/hr)
PROPANE GAS
(btu/hr)
KMI-20
21,000
23,000
43
KMI-40
45,000
44,000
68
KMI-60
65,000
66,000
94
KMI-90
90,000
90,000
123
KMI-120
125,000
125,000
170
MODEL NO.
"A"
(in)
KMI-20
18 7/8
KMI-40
33 7/16
KMI-60
47 15/16
KMI-90
62 1/2
KMI-120
91 9/16
GAS PRESSURES
MAXIMUM
MINIMUM
Connection
1/2″ NPT female thread
Natural Gas
14" W.C.
6.5" W.C.
Propane
14" W.C.
12" W.C.
SINGLE STAGE GAS PRESSURE
NATURAL GAS
PROPANE
Minimum
6.5″ W.C.
12″ W.C.
Maximum
14" W.C.
14″ W.C.
Manifold
5″* W.C.*
11″ W.C.
ENGINEERING SPECIFICATIONS
Energy Supply
Gas Connection
Electrical Connection
Alternating current AC, voltage; 24 V, 60 Hz with L, N and Ground (GND)
Power Consumption
12 W for single-stage infrared heaters
13.80
A
19.57
5.90
Single Stage
*5.25" W.C. for model KMI 90