Advanced Energy Thyro-A Скачать руководство пользователя страница 6

6

1.4 WARRAnTy

In the event of any claims in connection with the Modbus RTU, please contact 
us immediately quoting:
- Type designation
- Works number/Serial number
- Reason for the complaint
- Environmental conditions of the device
- Operating mode
- Period of use

Goods and services are subject to the general conditions of supply for
products of the electrical industry, and our general sales conditions.
Claims in connection with supplied goods must be submitted within one 
week of receipt, along with the delivery note.  Advanced Energy will rescind 
all obligations such as warranty agreements, service contracts, etc. entered 
into by Advanced Energy or its representatives without prior notice if main-
tenance and repair work is carried out using anything other than original Ad-
vanced Energy  spare parts or spare parts purchased fromAdvanced Energy.

Содержание Thyro-A

Страница 1: ...1 BUS MODULE MODBUS RTU fOr Thyro s Thyro A And thyro AX July 2014 DE EN V3...

Страница 2: ...ndustries GmbH Branch Office Warstein Belecke Emil Siepmann Stra e 32 D 59581 Warstein Phone 49 0 2902 763 0 http www advanced energy com Copyright No part of these operating instructions may be trans...

Страница 3: ...lts 10 2 6 4 Transport 10 3 Functions 11 3 1 Setpoint processing Thyro S 11 3 2 Setpoint processing Thyro A Thyro AX 12 3 3 Operating display 13 3 4 Additional functions for Thyro S Thyro A and Thyro...

Страница 4: ...ab 7 Controller actual values 21 Tab 8 Controller parameters 22 23 Tab 9 Status and error flags 25 26 List of illustrations and tables 4 5 Status and error communication 25 5 External connections 27 5...

Страница 5: ...the bus module is provided by an external 24 V d c power source 150 mA which is fed into X11 1 and X11 2 ground reverse battery protected The 24 V d c supply must be ungrounded when operating under SE...

Страница 6: ...y for products of the electrical industry and our general sales conditions Claims in connection with supplied goods must be submitted within one week of receipt along with the delivery note Advanced E...

Страница 7: ...ers that can lead to serious injuries or fatal injuries Warning Dangers that can lead to serious injuries or considerable damage to property caution Dangers that can lead to injuries and damage to pro...

Страница 8: ...for the power controllers used Danger Electric current Risk of injury from live parts risk of damage to the bus module Never operate the device without the cover Only carry out adjustments or wiring...

Страница 9: ...e device is immediately put out of operation and the maintenance personnel is informed 2 4 Personnel requirements Only qualified electro technical personnel who are familiar with the pertinent safety...

Страница 10: ...d in a cubicle Observe minimum spacing Ensure that the device cannot be heated up by heat sources below it see chapter 10 Technical data Ground the device in accordance with local regulations Connect...

Страница 11: ...module is fully functional only the analog signal of control terminal X22 1 however is used as a setpoint ON OFF X22 4 has ground potential Only the master setpoints are used by the bus module graded...

Страница 12: ...nt is accepted by the bus module as a setpoint The controller s terminal X22 1 can be directly connected to earth if an alternati ve operation is excluded X22 1 is switched The terminal X22 1 of Thyro...

Страница 13: ...o S Thyro A and Thyro AX By using a bus module additional functions for the power controllers Thyro S Thyro A and Thyro AX can be employed All the accessible parameters of both type ranges can be foun...

Страница 14: ...state between 1 to 247 at the bus module via the switch S501 1 to S501 7 4 2 Setting the transmission parameters The settings which are required for communication assimilation can be made via the DIP...

Страница 15: ...sustained Parity Works setting no parity This switch activates transmission with parity bit Even nOdd Works setting Odd With activated parity bit it is possible to switch between Even and Odd parity 2...

Страница 16: ...e J bus register address is always used i e also with Modbus within the telegrams 4 3 1 Read Holding Registers 0x03 With this telegram the master can read out one or more registers function code 0x03...

Страница 17: ...ro A Thyro AX Controller 2 are to be changed to 2 VAR in the bus module with the address 100 1 overflow into high byte Inquiry address function register Data CRC 100 6 1 6 0 2 224 3 Response address f...

Страница 18: ...a CRC 100 16 1 152 0 2 4 0 0 39 16 3 4 Response address function Register number CRC 100 16 1 152 0 2 200 46 Error Should the register s address lie outside the address location the Exception Response...

Страница 19: ...number of registers So that the following applies Register number 1152 128 8x128 ILLEGAL DATA VALUE The data in the inquiry are not permitted For example the number of registers to be read is too hig...

Страница 20: ...evice type at port 1 5 9 10 S 1A 2A r r 1 GER_2 Device type at port 2 5 9 10 S 1A 2A r r 2 GER_3 Device type at port 3 5 9 10 S 1A 2A r r 3 GER_4 Device type at port 4 5 9 10 S 1A 2A r r 4 GER_5 Devic...

Страница 21: ...90 Power L3 float 2 W r onlyThyro A2AHRLP1 Thyro AX2AHRLP2 92 Load voltage L3 float 2 V r onlyThyro A 2A Thyro AX 2A 94 Current L3 float 2 A r onlyThyro A H RL Thyro AX H RL 96 Mains voltage L3 integ...

Страница 22: ...duration 0 1000 period r r w r w 50 period R201 12 MP Minimum interval 0 10 period r w r w 3 period R201 13 TSMAX Maximum phase switch on time 0 T0 period r w r w 50 period 14 TSMIN Minimum phase swit...

Страница 23: ...res r w 38 SYNC_ADR Synchronous phase address 0 65535 period 2 r w r w 100 39 IMAB Impulse cut off with fault 0 65535 Bit coded r w r w r w 0 40 STA_RE Contr start contr analog setpoint value 0 4095...

Страница 24: ...dware setting is used when the mains returns For excep tions see or In the Thyro Tool mode switch S1 3 5 on On the parameters marked with are not given by the switches and Potis instead the stored val...

Страница 25: ...t5 Pulse Inhibit LED Load Fault LED a Test LED on dropped out Load Fault LED and Test LED on dropped out Mains Overvoltage AD_P_SPG_MAX Bit6 none energised none energised Master Slave error only with...

Страница 26: ...y alternately energised only withThyro A Thyro AX I limiting active Bit5 Pulse Inhibit LED and Load Fault LED flash slowly alternately energised only withThyro A Thyro AX P limiting active Bit6 Pulse...

Страница 27: ...nnecting diagram shows the essential functions of the bus module Fig 2 Block connecting diagram 2 Contact switch Shut Conduct bus data Open Only actual value inquiry 2 X1 to X8 to the Power Controller...

Страница 28: ...dually connectable ground 6 Ground 7 Earth potential for screen connection Allocation of the 3 terminal connector X11 X11 1 24 V X11 2 24 V ground X11 3 earthing connected earthing cable should be as...

Страница 29: ...stopbit The log begins with STX followed by an identification key the data and ends with a check sum Faulty logs are ignored 6 2 Modbus interface This interface in accordance with RS485 is designed f...

Страница 30: ...30 7 Connecting plans Thyro A Thyro AX Fig 3 Connecting plans Thyro A Thyro AX...

Страница 31: ...31 Fig 4 Connecting plans Thyro S 8 Connecting plans Thyro S...

Страница 32: ...cation Set configuration switch Carry out cabling Feed 24V d c green LED must light up bus module is ready for operation red LED stops blinking as soon as the Modbus starts operating Should errors occ...

Страница 33: ...n options Up to 8 Advanced Energy power controllers of the Thyro S Thyro A and Thyro AX series of types H1 H RL1 H RLP1 H RL2 and H RLP2 Function check Via LEDs Mounting On DIN rail Ambient temperatur...

Страница 34: ...000 849 Bus module connecting cable for 4 controllers 1 5 m long Data transmission in acc with ISO 11898 Quality standard in acc with DIN EN ISO 9001 CE conformity Low voltage directive 73 23 EEC EMC...

Страница 35: ...erature better B 10 C 55 C Humidity class B DIN EN 50 178 Tab 7 EN 60 721 Degree of contamination 2 DIN EN 50 178 Tab 2 Air pressure 900 mbar 1000 m above m sea level Index of protection IP00 DIN EN 6...

Страница 36: ...USA 970 221 4670 Main 970 221 5583 Fax www advanced energy com Specifications are subject to change without notice 2014 Advanced Energy Industries Inc All rights reserved Advanced Energy and Thyro S...

Страница 37: ...37...

Страница 38: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Advanced Energy 2000000842...

Отзывы: