* The table only shows the default configuration of the relay function.
It can be configured by Thyro-Tool family, which message shall be shown by
the relay an which not.
The relay only exists in h RL1, h RLP1, h RL2 or h RLP2 device, not in the h1
types.
DESCRIPTIOn:
Thyro-A/Thyro-AX
Thyro-S
Thyro-S, Thyro-A and Thyro-AX
LEDs
RELAy*
LEDs
RELAy*
Pulse blocking active
(bridge X2.1-X2.2open)
Bit0
Pulse Inhibit LED on
energised
none
energised
Mains frequency is 60 hz
Bit2
none
energised
none
energised
U limiting active
Bit4
Pulse Inhibit LED and Load
Fault LED flash slowly
alternately
energised
only with Thyro-A/Thyro-AX
---
I limiting active
Bit5
Pulse Inhibit LED and Load
Fault LED flash slowly
alternately
energised
only with Thyro-A/Thyro-AX
---
P limiting active
Bit6
Pulse Inhibit LED and Load
Fault LED flash slowly
alternately
energised
only with Thyro-A/Thyro-AX
---
Relay status (0=relay off/ 1=relay
on)
Bit8
none
on/off
none
on/off
Busmodul aktiv (0=no bus
module/1=bus modul active)
Bit11 none
energised
none
energised
Thyristor short-circuit (Thyro-S)
Bit14 only with Thyro-S
---
Test-LED a. Load fault LED
flash slowly
alternately
dropped out
failure in rotating field/
phase (only Thyro-A 2A or 3A/
Thyro-AX 2A or 3A)
Bit15 Pulse Inhibit LED and Test
LED flash slowly simulta
-
neously
dropped out only with Thyro-A/Thyro-AX
---
TAB. 9 B ERROR fLAGS (STATUS)