![Advanced Energy HFV 8000 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/advanced-energy/hfv-8000/hfv-8000_user-manual_2855945057.webp)
5705211-C
Communication Interfaces
4-21
HFV 8000 Generator
5
starting
frequency
Sets the starting frequency. Send four bytes,
least significant byte first, representing the
starting frequency value in Hertz.
Note:
This command is invalid when the unit
is in center frequency mode.
• The value must be greater than or equal
to the value set by command
3
(
minimum frequency
) and less than or
equal to the value set by command
4
(
maximum frequency
).
• For example, enter 2000000
(2,000,000 Hz).
Read back with command
135
. See also
“Frequency Limits” on page 5-14
.
4
1
CSR only
7
reset tuning
parameters
Resets tuning parameters to factory defaults.
Send 1 byte to select the setting:
• 0 = Keep current settings
• 1 = Factory defaults
1
1
CSR only
11
frequency
rate of
change
Specifies the frequency rate of change. Send
two bytes, least significant byte first,
representing the frequency rate of change in
seconds.
•
Accepts a value of 5 to 1000 (0.005 s to
1.000 s, decimal is implied)
Read back with command
141
. See also
“Frequency rate of change (ms)” on
page 5-15
.
2
1
CSR only
12
set
regulation
mode
Sets regulation mode. Send one data byte,
indicating the desired mode:
• 2 = Forward power regulation
• 3 = Load (delivered) power regulation
Read back with command
132
.
1
1
CSR only
Table 4-7.
Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание HFV 8000
Страница 1: ...HFV 8000 Generator 2 MHz 208 V Input with DeviceNet March 2004 5705211 C User Manual...
Страница 2: ......
Страница 3: ...User Manual HFV 8000 Generator 2 MHz 208 V Input with DeviceNet 5705211 C...
Страница 6: ...iv 5705211 C Advanced Energy...
Страница 14: ...xii 5705211 C Advanced Energy...
Страница 22: ...1 8 Safety and Product Compliance Guidelines 5705211 C Advanced Energy...
Страница 26: ...2 4 Product Overview and Theory 5705211 C Advanced Energy...
Страница 36: ...3 10 Product Specifications 5705211 C Advanced Energy...
Страница 94: ...4 58 Communication Interfaces 5705211 C Advanced Energy...
Страница 97: ...5705211 C Installation Setup and Operation 5 3 HFV 8000 Generator Front Panel Drawing Figure 5 1 Front view...
Страница 114: ...5 20 Installation Setup and Operation 5705211 C Advanced Energy...
Страница 128: ...6 14 Troubleshooting and Global Customer Support 5705211 C Advanced Energy...
Страница 132: ...iv 5705211 C Advanced Energy...
Страница 134: ...5705211 C ii HFV 8000 Generator...
Страница 140: ...5705211 C viii HFV 8000 Generator...
Страница 141: ...ix 5705211 C Advanced Energy...
Страница 142: ...Index x 5705211 C Advanced Energy...