5 PROPER USE OF THE PRODUCT

The suction caser has been designed to be installed for the pneumatic transport of pellets or other 
biomass fuels with a medium-fi ne size;
it has the task of extracting the fuel from the bottom of any hopper tank.

This product is suitable for the extraction of biomass fuel such as pellets, olive pomace, 
wood chips, crushed shells of dried fruit, corn, but it cannot work with fuels having a very 
fi ne size, or having excessive dimensions and, in any case, having lengths over 40 mm or 
diameter greater than 15 mm.
It is recommended to use only ENplus A1 certifi ed pellet.

To provide the job for which it was designed, the suction case must be connected to a control 
panel called that controls the operation of the entire pneumatic transport system or to an integrated 
central vacuum unit called.
Once installed and connected, the suction case extracts the fuel until the tank is completely 
empty; by the movement of the rod-crank mechanism positioned in front of the suction inlet, a 
possible blockage or clogging of the inlet itself because of slag or irregular dimensions fuel is 
avoided.

4 PACKAGING CONTENT

After opening the packaging, verify that the material contained in it conforms to the following list:
1) Extraction system
2)  Assembly, use and maintenance manual
3)  Flow regulator
4)  gum s 2 hose clamps
5)  Warranty form  

2

3

4

M

anuale

 T

ecnic

o

1

5

Содержание VACU MATIC FREE

Страница 1: ...12 ASSEMBLY USE AND MAINTENANCE MANUAL Fuel extraction system VACU MATIC FREE...

Страница 2: ......

Страница 3: ...fety symbols 6 4 PACKAGING CONTENT 7 5 PROPER USE OF THE PRODUCT 7 5 1 Caratteristiche del magazzino di stoccaggio 8 6 INSTALLATION 8 6 1 Instruction for the installation of systems 8 6 2 Positioning...

Страница 4: ...h care for the entire operative life of the product The main objective of this manual is to make known the proper and safe way to use the equipment No part of this manual may be reproduced copied or s...

Страница 5: ...ower W 15 Max absorp on A 0 14 Fuse 5x20 T2A Insula on class 1 Revolu ons per minute rpm 12 Rated torque Nm 5 Weight Kg 3 1 Measurement A mm 185 Measurement B mm 108 Measurement C mm 235 Measurement D...

Страница 6: ...NT Danger of serious personal injuries During maintenance operations always disconnect the power supply and make sure that it cannot be restored DANGER OF CUTTING Danger of serious personal injuries D...

Страница 7: ...er 40 mm or diameter greater than 15 mm It is recommended to use only ENplus A1 certified pellet To provide the job for which it was designed the suction case must be connected to a control panel call...

Страница 8: ...e product should not be exposed to atmospheric agents and should not be installed in areas subject to high humidity possible flooding high temperatures and dust presence 6 1 Instructions for the insta...

Страница 9: ...adius of the curves must be equal to or greater than 0 5 meters 6 sections of pipes that include both positive and negative siphons must be avoided 7 the sections of horizontal pipes must be kept perf...

Страница 10: ...so that it is not such as to cause blockages in the system To procede with this adjustment close or open the ventilation cuts by forward or backward the regulation sleeve see fig 2 By closing the cut...

Страница 11: ...power outlet In the event of a protection circuit breaker intervention during the operation of the suction case the polarity of the plug must be inverted invert phase with neutral F0030683 ALARM MICRO...

Страница 12: ...trical system to which it is connected the rod crank system operates regularly there are no foreign bodies in the storage tank For the first time just place a small amount of fuel in the storage tank...

Страница 13: ...each filling of the storage tank or at least yearly The checks to be carried out at least yearly are Check the antistatic pipe grounding conditions and the electrical system conditions Check the elec...

Страница 14: ...en In the 4 weeks after the fuel filling enter only with a CO detector Aerate the storage room for at least 15 minutes before entering and keep the door open during your permanence Ensure an adequate...

Страница 15: ...rom 1 accident abuse misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection to an improper volt...

Страница 16: ...Regulation EC 1907 2006 REACH or registration evaluation authorization and restriction of chemical substances Although in the working cycles of raw materials and our products such substances are not...

Страница 17: ...17 English 18 07 22 Rev 1 0 5...

Страница 18: ...Suction case with motorized nozzle 18 18 07 22 Rev 1 0 5...

Страница 19: ......

Страница 20: ...VACU MATIC FREE F0920525 2 info advanceeasymoving com www advanceeasymoving com...

Отзывы: