background image

Suction case with motorized nozzle

4

18/07/22 Rev:1.0.5

1 INTRODUCTION

Dear customer,
the manufacturer would fi rstly like to thank you for the choice you made in buying an product, whose 
technical features will certainly meet Your needs.
Our products have been designed and manufactured in total compliance with the current regulations, by 
choosing the best materials to obtain durability and ease of use of the product.
We ask you, therefore, to read this manual carefully and completely, following strictly the instructions 
contained herein.

1.1 Use of this manual

The instruction manual is a document drawn up by the manufacturer and is part of the product: it 
integrates the specifi c rules of application and general rules for people, animals and objects safety. In the 
event that the product is resold, handed over, rented or sold to others, it must always be accompanied 
by this manual; therefore, it is recommended to use and keep it with care for the entire operative life of 
the product.
The main objective of this manual is to make known the proper and safe way to use the equipment.
No part of this manual may be reproduced, copied, or shared in any way, without the written permission 
of the manufacturer.
The manufacturer reserves the right to make improvements or modifi cations to this manual
and to the equipment at any time, without obligation to advise third parties.

2 WARNINGS

• Do not use the machine for any improper use.
• Do not let children near the machine.
• This unit must not be used by people (including children) with reduced physical, sensory or mental 
capabilities, or with lack of experience and knowledge, unless they are supervised or instructed in the 
use of the unit by a person responsible for their safety.
• Use only original spare parts.
• Do not put parts of the body into contact with the machine before having removed the electrical power.
• Disconnect the power supply when a long period of inactivity is expected.
 
The manufacturer declines any liability or guarantee, if the buyer or anyone
makes changes or even minor modifi cations to the purchased product.

Содержание VACU MATIC FREE

Страница 1: ...12 ASSEMBLY USE AND MAINTENANCE MANUAL Fuel extraction system VACU MATIC FREE...

Страница 2: ......

Страница 3: ...fety symbols 6 4 PACKAGING CONTENT 7 5 PROPER USE OF THE PRODUCT 7 5 1 Caratteristiche del magazzino di stoccaggio 8 6 INSTALLATION 8 6 1 Instruction for the installation of systems 8 6 2 Positioning...

Страница 4: ...h care for the entire operative life of the product The main objective of this manual is to make known the proper and safe way to use the equipment No part of this manual may be reproduced copied or s...

Страница 5: ...ower W 15 Max absorp on A 0 14 Fuse 5x20 T2A Insula on class 1 Revolu ons per minute rpm 12 Rated torque Nm 5 Weight Kg 3 1 Measurement A mm 185 Measurement B mm 108 Measurement C mm 235 Measurement D...

Страница 6: ...NT Danger of serious personal injuries During maintenance operations always disconnect the power supply and make sure that it cannot be restored DANGER OF CUTTING Danger of serious personal injuries D...

Страница 7: ...er 40 mm or diameter greater than 15 mm It is recommended to use only ENplus A1 certified pellet To provide the job for which it was designed the suction case must be connected to a control panel call...

Страница 8: ...e product should not be exposed to atmospheric agents and should not be installed in areas subject to high humidity possible flooding high temperatures and dust presence 6 1 Instructions for the insta...

Страница 9: ...adius of the curves must be equal to or greater than 0 5 meters 6 sections of pipes that include both positive and negative siphons must be avoided 7 the sections of horizontal pipes must be kept perf...

Страница 10: ...so that it is not such as to cause blockages in the system To procede with this adjustment close or open the ventilation cuts by forward or backward the regulation sleeve see fig 2 By closing the cut...

Страница 11: ...power outlet In the event of a protection circuit breaker intervention during the operation of the suction case the polarity of the plug must be inverted invert phase with neutral F0030683 ALARM MICRO...

Страница 12: ...trical system to which it is connected the rod crank system operates regularly there are no foreign bodies in the storage tank For the first time just place a small amount of fuel in the storage tank...

Страница 13: ...each filling of the storage tank or at least yearly The checks to be carried out at least yearly are Check the antistatic pipe grounding conditions and the electrical system conditions Check the elec...

Страница 14: ...en In the 4 weeks after the fuel filling enter only with a CO detector Aerate the storage room for at least 15 minutes before entering and keep the door open during your permanence Ensure an adequate...

Страница 15: ...rom 1 accident abuse misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection to an improper volt...

Страница 16: ...Regulation EC 1907 2006 REACH or registration evaluation authorization and restriction of chemical substances Although in the working cycles of raw materials and our products such substances are not...

Страница 17: ...17 English 18 07 22 Rev 1 0 5...

Страница 18: ...Suction case with motorized nozzle 18 18 07 22 Rev 1 0 5...

Страница 19: ......

Страница 20: ...VACU MATIC FREE F0920525 2 info advanceeasymoving com www advanceeasymoving com...

Отзывы: