RECOVERY WATER SYSTEM
SQUEEGEE SPRING CHECK/REPLACEMENT (All models, with aluminium squeegee)
Check
1. Drive the machine on a level floor.
2. • (For
Adfinity™ X20R, 20D, X20D, X20C, X24D
) Turn the ignition key (80) to “0”.
• (For
Adfinity™ 17ST, 20ST
) Turn off the switches (71) and (73).
3. Check that the springs (A) and (B) push the squeegee (C) on the floor correctly.
4. If necessary, disassemble and replace the springs according to the following procedure.
Disassembly
5. Remove the squeegee (see the procedure in the relevant paragraph).
6. Lift the deck by pressing the pedal (11).
7. Grasp the handlebar (2) and lower the front part of the machine.
8. Remove the cotter pin (D).
9. Disengage the end (E) of the left spring (F) from the housing (G).
10. Remove the left spring (F).
11. Repeat steps 8, 9 and 10 for the right spring (H).
Assembly
12. Assemble the springs by performing steps 5 to 11 in the reverse order.
A
B
C
D
E
G
H
F
S301557A