Daily Threshold
The Daily Threshold option is used to display daily
alarm threshold levels for multiple Performance
Monitoring statistics. From this menu, navigate to a
menu to set the threshold to the desired level and enable
an alarm to be issued if that threshold is exceeded.
Quarter Hourly Threshold
The Quarter Hourly Threshold option is used to display
Performance Monitoring threshold levels for 15-minute
intervals. Thresholds and alarms can be set as described
above under “Daily Threshold.”
Reset Performance Registers for OC-3
The Reset Performance Register for OC-3 option is
used to resets performance registers to N/A (not
available), except for the current interval, which is set to
“0.”
Protection Configuration Menu
Figure 16
represents the OC-3 MUX Protection
Configuration menu where Manual Switches and
Switch INHIBITS are set. A manual switch will not
override a Switch Inhibit. Descriptions of the menu
options are explained in the following subsections.
MUX Operational Status
The MUX Operational Status field indicates whether
the module is the Active controller of the clock source
copy switching (Online) or in Standby mode (Offline).
MUX APS Lockout Status
THe MUX APS Lockout Status indicates whether the
clock controller is allowed to switch to the protection
(ALLOWED) or are prohibited from switching to
protection (INHIBIT). MUX APS Lockout overwrites
DS3 APS Lockout.
MUX APS Switch
The MUX APS Switch option is used to manually
switch the DS3 traffic and the Clock Controller. When
traffic is split, all traffic will follow the Clock
Controller. When switching the Clock Controller, the
MUX also attempts to force the Access cards to switch
to receive the DS1 traffic from the Online MUX.
Figure 16. Protection Configuration Menu
DS3 #1 Operational Status
The DS3 #1 Operational Status field indicates whether
this unit sources the DS3 #1 transmit traffic to the Quad
BNC connector on the backplane (Online) or the unit is
in Standby mode (Offline).
DS3 #1 APS Lockout Status
The DS3 #1 APS Lockout Status field indicates whether
the STS-1 connected to DS3 #1 is allowed to switch
(Allow) on a Section-, Line-, or Path-level fault from
the incoming OC-3 signal, or is prohibited (Inhibit).
Shelf: 1 Slot: B Total Access System 01/08/03 15:41
Unacknowledged Alarms: None
Protection Configuration
Mux Operational Status : Online
2. Mux APS Lockout Status : Allow
Perform Mux APS switch
DS3 #1 Operational Status : Online
6. DS3 #1 APS Lockout Status : Allow
Perform APS switch on DS3 #1
DS3 #2 Operational Status : Online
10. DS3 #2 APS Lockout Status : Allow
Perform APS switch on DS3 #2
Selection: