61287737F3-13A
5
LED
S
The LEDs are located beneath the plastic housing and are only
visible after applying power. The following table provides the LED
status during normal operations.
If AOE Auto Upgrade is active, a new ONT installation will be
detected and a new software download will commence. This may
take 5 to 10 minutes to complete.
Label
Status
Indication
POWER
Off
Green
AC or battery off
No Failure
BAT-
TERY
2
2
Off
Green
Green
Flashing Slow
Green
Flashing Fast
ONT boot or battery miss-
ing/not equipped
Battery equipped and no
battery alarms present
Loss of AC, on battery
Battery low
FAIL
Off
Red
Unit is working properly
Red after power-up until
initialization is complete
ETH
1-4
2
Off
Green
Green
Flashing Fast
Link is down or not
equipped
Link is up
Data is being sent or
received
POTS
2
Off
Green
Green
Flashing Slow
Unequipped or on-hook
and not ringing
Line is in use, not just Off-
Hook
Line in ringing state
MGMT
2
2
Off
Red
Red Flashing
Slow
Red Flashing
Fast
DS signal detected and is
within margins
No DS signal detected
DS signal is present but
marginal
Software Upgrade failed
WLAN
WLAN is not provisioned for this release.
S
PECIFICATIONS
Refer to the following for a list of all specifications for the ONT.
■
Electrical
♦
Nominal Voltage: 12.0 VDC
♦
Minimum Voltage: 10.0 VDC
♦
Maximum Voltage: 13.9 VDC
♦
Power Consumption: 1.06 Amps @12.0 VDC
♦
AC Power: Included Switching Adapter input range of 100 -
240 VAC, 50/60 Hz, with a nominal output of 12 VDC
■
Optical
♦
TX min power: –5.5 dBm
♦
TX max power: –1.0 dBm
♦
RSSI max sensitivity: –27.0 dBm
♦
RX overload: –8 dBm
♦
TX wavelength: 1310 nm typical
♦
RX wavelength: 1490 nm typical
■
Physical
♦
Height: 1.55 in. (4.0 cm)
♦
Depth: 6.0 in. (15.2 cm)
♦
Width: 10.25 in. (26.0 cm)
♦
Weight: 2 lbs (0.9 kg)
■
Environmental
♦
Operational Temperature: –5°C to +45°C
♦
Storage Temperature: –40°C to +70°C
♦
Relative Humidity: 0% to 95%, noncondensing
M
AINTENANCE
The ONT does not require routine hardware maintenance for
normal operation. We do not recommend that you attempt repairs
in the field. Repair services may be obtained by returning the
defective unit to ADTRAN. Refer to the warranty for further infor-
mation. Field support for software is provided through upgrade
facilities.
S
AFETY
AND
R
EGULATORY
Refer to the
Safety and Regulatory Notice for this product
(61287737F3-17) for detailed safety and regulatory information.
Reportez-vous à la sûreté et la réglementation Avis de conformité
pour ce produit (61287737F3-17) pour la sécurité des
informations détaillées et réglementaires.
Wenden Sie sich an die Sicherheit und Regulatory Compliance
und Datenschutz zu diesem Produkt (61287737F3-17) für
detaillierte Sicherheits-und aufsichtsrechtliche Informationen.