61287737F3-13A

3

Step 2: Connect POTS

f

     

CAUTION!

The product is intended for indoor use only. POTS cables and 
attached equipment are intended for use within the same building 
with equipotential bonding, and not intended to be placed in 
separate buildings or structures. Failure to deploy as described 
could result in permanent damage from lightning or other 
electrical events and voids the Warranty. 

If POTS cables are unavailable, refer to 

Figure 2

 and use the 

following procedure to create the POTS cables.

1. Trim the insulation for the subscriber POTS cables.
2. Refer to 

Figure 2

 and connect the twisted-pair Tip (green) 

and Ring (Red) to the RJ-11 connector using an RJ-11 
crimper.

3. Insert the RJ-11 connector in the appropriate POTS jack 

(

POTS 1, POTS 2

).

Figure 2. RJ-11 Pin-out

1 = Not Connected

2 = Tip

3 = Ring

4 = Not connected

Step 3: Connect Ethernet

f

     

CAUTION!

The product is intended for indoor use only. Ethernet cables 
and attached equipment are intended for use within the same 
building with equipotential bonding, and not intended to be 
placed in separate buildings or structures. Failure to deploy as 
described could result in permanent damage from lightning or 
other electrical events and voids the Warranty. 

If it is necessary to connect the ports to remote outdoor 
equipment or between structures then add an appropriate 
protection device per the following: ADTRAN’s Ethernet Port 
Protection Device (EPPD) (P/N: 1700502G1) must be 
connected between the unit and the outside plant cable. Use 
of any Ethernet protector other than ADTRAN’s for this 
purpose will void the user’s Warranty.

The ONT supports four 1 Gigabit (10/100/1000Base-T) 

connections (

ETH 1

 to 

ETH 4

). 

If Ethernet cables are unavailable, use the following procedure 
and table to build the Ethernet cables.

1. Trim the insulation for the subscriber Ethernet cable.
2. Connect the wires per the following table using an RJ-45 

Crimper.

3. Insert the CAT 6 rated cable in the appropriate Ethernet 

ports (

ETH 1

 to 

ETH 4

).

Ethernet RJ-45 Pin-out

Pin

Name

Description

Color Code

1

TRD0+

Transmit/Receive Positive

White/Orange

2

TRD0-

Transmit/Receive Negative

Orange

3

TRD1+

Transmit/Receive Positive

White/Green

4

TRD2+

Transmit/Receive Positive

Blue

5

TRD2-

Transmit/Receive Negative

White/Blue

6

TRD1-

Transmit/Receive Negative

Green

7

TRD3+

Transmit/Receive Positive

White/Brown

8

TRD3-

Transmit/Receive Negative

Brown

Содержание Total Access 324E

Страница 1: ...tionally by a customer provided Uninterruptible Power Supply UPS AC DC Power Adapter The power feed is supplied through a 12 VDC Power Adapter that is included with the ONT The Power Adapter operates from a wall socket input of 100 240 VAC 50 60 Hz with a nominal output of 12 VDC The total power consumption with 4 Ethernet Ports running and both POTS lines off hook is approximately 13 0 Watts UPS ...

Страница 2: ...ion test set PON power meter with wavelength filtering Fiberscope or videoscope Two 8 Pan Head screws 1 inch or greater in length Assorted tie wraps for securing cabling and wiring Fiber optic connections require the following Fiber optical fusion splice tools ODC Fiber cleaning tool SC Fiber connector Installation Steps To install the ONT complete the following steps Step 1 Position the ONT The O...

Страница 3: ...ailure to deploy as described could result in permanent damage from lightning or other electrical events and voids the Warranty If it is necessary to connect the ports to remote outdoor equipment or between structures then add an appropriate protection device per the following ADTRAN s Ethernet Port Protection Device EPPD P N 1700502G1 must be connected between the unit and the outside plant cable...

Страница 4: ...n Battery 1 3 UPS Status Battery Missing 2 4 Signal Return 5 Power 12 V Return 6 UPS Status Replace Battery 3 7 UPS Status Low Battery 4 8 No Connection 8 7 6 5 4 3 2 1 Step 4 Install Fiber C CAUTION LASER RADIATION 1310 nm to 1490 nm Do not view directly with optical instruments This product contains a Class 1 Laser module that complies with FDA 21 CFR 1040 10 1040 11 and IEC 60825 1 Fiber is ins...

Страница 5: ...the ONT Electrical Nominal Voltage 12 0 VDC Minimum Voltage 10 0 VDC Maximum Voltage 13 9 VDC Power Consumption 1 06 Amps 12 0 VDC AC Power Included Switching Adapter input range of 100 240 VAC 50 60 Hz with a nominal output of 12 VDC Optical TX min power 5 5 dBm TX max power 1 0 dBm RSSI max sensitivity 27 0 dBm RX overload 8 dBm TX wavelength 1310 nm typical RX wavelength 1490 nm typical Physica...

Страница 6: ...opyright 2020 ADTRAN Inc All Rights Reserved ADTRAN CUSTOMER CARE From within the U S 1 888 423 8726 From outside the U S 1 256 963 8716 PRICING AND AVAILABILITY 1 800 827 0807 61287737F3 13A Documentation for ADTRAN Network Solutions products is available for viewing and download directly from the ADTRAN Support Community website Go to https supportforums adtran com welcome Registration is requir...

Отзывы: