This Quick Start supports the Total Access 324 Active Ethernet 
Indoor Optical Network Terminal (ONT). The illustration above 
displays the rear of the ONT and a cut-away of the top depicting 
status LEDs. 

Ports/Connectors

2 POTS Ports

4 Gigabit Ethernet Ports

DC Power Plug

UPS Connector

SC Fiber Connector

Voice Processing (POTS1, POTS2)

POTS uses inband signaling tones and currents to determine call 
status (for example, Call Request). Because POTS allows for the 
transfer of audio signals below 3.3 kHz, POTS systems are also 
used for modems that allow data transmission, referred to as “dial 
up connections.”

Ethernet Interface (ETH1, ETH2, ETH3, ETH4)

The ONT supports data service through four 10/100/1000Base-T 
Ethernet interfaces. 

Total Access 

324E Active Ethernet Indoor ONT

2 POTS + 4 GigE

September 2020

61287737F3-13A

P/N: 1287737F3

Power (PWR)

Power is supplied by an AC/DC Power Adapter or optionally by a 
customer provided Uninterruptible Power Supply (UPS).

AC/DC Power Adapter

The power feed is supplied through a 12 VDC Power Adapter that 
is included with the ONT. The Power Adapter operates from a wall 
socket input of 100 – 240 VAC, 50/60 Hz, with a nominal output of 
12 VDC. The total power consumption with 4 Ethernet Ports 
running and both POTS lines off-hook is approximately 13.0 
Watts.

UPS

The ONT provides an optional connector, labeled 

UPS

 for a 

customer provided UPS. The UPS powers the ONT and provides 
a battery back-up supplying continuous 12 VDC when the primary 
power is lost. 
The ONT can be safely powered by both the AC/DC Power 
Adapter and UPS simultaneously. However, to save quiescent 
power dissipated by the AC/DC Power Adapter, it is recom-
mended that the AC/DC Power Adapter be removed when using 
the UPS. To use UPS, the ADTRAN Cable Assy (P/N: 
1287402G1) is required.

Fiber

Fiber is supplied to the ONT using an SC Fiber connection located 
behind a removable protective panel.

Fiber Port

ON/OFF

PWR

ETH1

ETH2

ETH3

ETH4

UPS

POTS1

POTS2

POWERBA

TTERY

FAIL

ETH4

ETH3

ETH2

ETH1

POTS

MGMT

WLAN

Содержание Total Access 324E

Страница 1: ...tionally by a customer provided Uninterruptible Power Supply UPS AC DC Power Adapter The power feed is supplied through a 12 VDC Power Adapter that is included with the ONT The Power Adapter operates from a wall socket input of 100 240 VAC 50 60 Hz with a nominal output of 12 VDC The total power consumption with 4 Ethernet Ports running and both POTS lines off hook is approximately 13 0 Watts UPS ...

Страница 2: ...ion test set PON power meter with wavelength filtering Fiberscope or videoscope Two 8 Pan Head screws 1 inch or greater in length Assorted tie wraps for securing cabling and wiring Fiber optic connections require the following Fiber optical fusion splice tools ODC Fiber cleaning tool SC Fiber connector Installation Steps To install the ONT complete the following steps Step 1 Position the ONT The O...

Страница 3: ...ailure to deploy as described could result in permanent damage from lightning or other electrical events and voids the Warranty If it is necessary to connect the ports to remote outdoor equipment or between structures then add an appropriate protection device per the following ADTRAN s Ethernet Port Protection Device EPPD P N 1700502G1 must be connected between the unit and the outside plant cable...

Страница 4: ...n Battery 1 3 UPS Status Battery Missing 2 4 Signal Return 5 Power 12 V Return 6 UPS Status Replace Battery 3 7 UPS Status Low Battery 4 8 No Connection 8 7 6 5 4 3 2 1 Step 4 Install Fiber C CAUTION LASER RADIATION 1310 nm to 1490 nm Do not view directly with optical instruments This product contains a Class 1 Laser module that complies with FDA 21 CFR 1040 10 1040 11 and IEC 60825 1 Fiber is ins...

Страница 5: ...the ONT Electrical Nominal Voltage 12 0 VDC Minimum Voltage 10 0 VDC Maximum Voltage 13 9 VDC Power Consumption 1 06 Amps 12 0 VDC AC Power Included Switching Adapter input range of 100 240 VAC 50 60 Hz with a nominal output of 12 VDC Optical TX min power 5 5 dBm TX max power 1 0 dBm RSSI max sensitivity 27 0 dBm RX overload 8 dBm TX wavelength 1310 nm typical RX wavelength 1490 nm typical Physica...

Страница 6: ...opyright 2020 ADTRAN Inc All Rights Reserved ADTRAN CUSTOMER CARE From within the U S 1 888 423 8726 From outside the U S 1 256 963 8716 PRICING AND AVAILABILITY 1 800 827 0807 61287737F3 13A Documentation for ADTRAN Network Solutions products is available for viewing and download directly from the ADTRAN Support Community website Go to https supportforums adtran com welcome Registration is requir...