Most personal computers or laptops can run communications software that emulates a VT100
terminal. Windows programs such as Terminal or HyperTerminal are two such examples in
the Windows format, but there are many other adequate, commercially available software
packages, virtually all of which allow the PC or laptop to emulate a VT100 terminal. Certain
configuration items must be set on a PC or laptop to act as a VT100 terminal for the MX3216
system.
1. Set the parameters of the communications software to the following settings:
• 115200 baud rate or less
• 8 data bits
• No parity
• 1 stop bit
• No flow control
2. Set the PC for direct connect on the appropriate communications port (as opposed to dial-
up connection).
3. Plug the male end of the data cable into the MX3216 Controller Card. Make connection to
the PC or laptop as appropriate for the equipment.
Ethernet Interface
Connection to the MX3216 system can be made through a rear panel Ethernet port or a front
panel Ethernet port if the optional MX3RMM is installed.
1. Connect the local Ethernet port to another 10/100 Mbps Ethernet port using either a
straight-through or cross-over cable.
NOTE
The IP address, subnet mask, and default gateway must be set
through the front panel craft port initially before an Ethernet port
can be used.
2. To log on using a Telnet application, set the IP address to the appropriate address, and set
either the default port to 23 or use the secondary port, which is user-defined.
Remote Interface
Connection to the MX3216 system can be made through a remote logon by a T1/FT1 when
using the MX3RMM.
1. To enable remote Telnet access, configure the built-in 3-to-1 cross connect so that the
MX3RMM has access to the DS1s that are transporting the PPP data. Also, configure the
MX3RMM to properly terminate the DS1 and enable the appropriate DS0s. The IP
address, subnet mask, and default gateway must be configured as well.
2. To log on using a Telnet application, set the IP address to the appropriate address, and set
either the default port to 23 or use the secondary port, which is user-defined.
Содержание MX3216
Страница 20: ...MX3216 System Manual 1 6 61189008L1 1B This page is intentionally blank...
Страница 64: ...MX3216 System Manual 5 8 61189008L1 1B This page is intentionally blank...
Страница 186: ...MX3216 System Manual 6 122 61189008L1 1B This page is intentionally blank...
Страница 188: ...MX3216 System Manual 7 2 61189008L1 1B This page is intentionally blank...
Страница 190: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...