The following two sections detail the power dissipation requirements for the MX3216
Controller Card, the MX3RMM, and the MX3216 system.
Module Configurations
provides the heat dissipation data for each module at –48 VDC (operating range of
–42 VDC to –60 VDC) and ±24 VDC (operating range of ±22 VDC to ±27 VDC).
System Configurations
provides the total heat dissipation at –48 VDC and ±24 VDC for the different
MX3216 system configurations.
Table 2-5. Heat Dissipation
Part Number
Equipment
Heat Dissipation
at –48 VDC
Heat Dissipation
at ±24 VDC
1189004L1
MX3RMM
3.0 watts
3.0 watts
1189007L1
MX3 Fan Module
2.39 watts
2.28 watts
1189008L1
MX3216
14.4 watts
14.2 watts
1189008L1
MX3216 (redundant pair)
21.6 watts
21.6 watts
Table 2-6. Total Heat Dissipation
Part Number
Quantity
Total Heat Dissipation
at –48 VDC
Total Heat Dissipation
at ±24 VDC
MX3216 (non-redundant) with one MX3RMM
1189004L1
1
16.2 watts
14.1 watts
1189007L1
1
1189008L1
1
MX3216 (redundant) with one MX3RMM
1189004L1
1
24.0 watts
20.3 watts
1189007L1
1
1189008L1
2
Содержание MX3216
Страница 20: ...MX3216 System Manual 1 6 61189008L1 1B This page is intentionally blank...
Страница 64: ...MX3216 System Manual 5 8 61189008L1 1B This page is intentionally blank...
Страница 186: ...MX3216 System Manual 6 122 61189008L1 1B This page is intentionally blank...
Страница 188: ...MX3216 System Manual 7 2 61189008L1 1B This page is intentionally blank...
Страница 190: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806...