The Huntsville Unit will have 23 entries in its PVC configuration table to correspond to the 23
remote sites.
4.
For the first entry, use the right arrow to select
DLCI
; then press
<Enter>
. Type in 16 and press
<Enter>
.
5.
Use the right arrow to select
DBU DLCI
; then press
<Enter>
. Type in 20 and press
<Enter>
.
Notice that the TELCO-assigned DLCI of 16 for Huntsville's Frame Relay link to Atlanta is pro-
grammed in the
DLCI
field. The TELCO-assigned DLCI of 20 for Atlanta's Frame Relay link to
Huntsville is programmed in the
DBU DLCI
field. These two entries are critical for proper dial
backup operation.
6.
Use the right arrow to select
DBU P
HONE
N
UMBER
; then press
<Enter>
. Type in 12565552000 and
press
<Enter>
. The phone number that the Huntsville IQ 710 will dial to reach the Atlanta IQ 710 to
establish a dial backup connection has now been programmed.
7.
Use the right arrow to select
DBU O
N
I
NACTIVE
; then press
<Enter>
.
8.
Down arrow to select
E
NABLED
; then press
<Enter>
. This allows the Huntsville IQ 710 to dial out to
the IQ 710 in Atlanta in the event that DLCI 16 is advertised as Inactive by the Frame Relay switch.
At this point all PVC options have been configured for basic Frame Relay dial backup to Atlanta.
The PVC entry for DLCI 16 on the Huntsville IQ 710 should look like the screen shown in Figure
16. The remaining options may be left at their default values. The
CIR
,
S
EQ
N
UM
C
HECKING
,
D
ELAY
M
EASUREMENT
, and
STATS O
PTION
are features not related to dial backup. For an explana-
tion of these features please refer to the IQ 710 User Manual.
Содержание IQ 710
Страница 14: ...IQ 710 System Manual 2002 ADTRAN Inc ...
Страница 82: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 82 ...
Страница 88: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 88 ...
Страница 94: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 94 ...
Страница 98: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 98 ...
Страница 102: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 102 ...
Страница 106: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 106 ...
Страница 120: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 120 ...
Страница 126: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 126 ...
Страница 132: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 132 ...
Страница 140: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 140 ...
Страница 144: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 5 Detail Level Procedures Page 144 ...
Страница 146: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 6 Configuration Guides Page 146 ...
Страница 192: ...IQ 710 System Manual 2002 ADTRAN Inc 61202800L1 1B IQ 710 Section 6 Configuration Guides Page 192 ...
Страница 312: ...61202800L1 1B IQ 710 Section 7 N FormAnt Page 312 IQ 710 System Manual 2002 ADTRAN Inc ...