61213075L2-5E
Issue 5, February 2011
5
Fuse
The input current is fused at 1.0 amp on each NIU3 PM
and cannot be replaced in the field.
Options
Options for test time out, in-band loopback enable, keep
alive signal, and customer transmit level are available
through the Provisioning menu screen. There are no
hardware options on the NIU3 PM. Framing is automat-
ically detected as the DS3 signal passes through the
unit.
3. TURNUP
When inserted into a housing with power applied, the
STATUS
LED illuminates red while the NIU3 PM
performs a self-test. If the self-test passes, the
STATUS
LED illuminates green and the remaining LEDs go
through an on/off sequence indicating the NIU3 PM is
online. If the test fails, the
STATUS
LED remains red
and the host bypass relays will maintain data flow
around the NIU3 PM. Shutdown procedures are not
required.
LED Indicators
LED indicators on the NIU3 PM front panel display
status during normal, trouble, and test operation.
describes the LED indicators.
Table 2. LED Indications
LED
Color
Status
Description
STATUS
Green
Red
On
On
Off
Normal operation
Card malfunction (bypass operation enabled)
No power
NTWK LOS/AIS
Red
Amber
On
On
Off
DS3 signal not present at network interface
AIS present at network interface
DS3 signal present at network interface
NTWK C-BIT
Green
Amber
On
Off
On
C-Bit framing detected at network interface
C-Bit framing not detected at network interface
C-Bit framing detected, Tx idle
NTWK M13
Green
Amber
On
Off
On
M13 framing detected at network interface
M13 framing not detected at network interface.
M13 framing detected, Tx idle
NTWK LBK
Amber
Flashing
Flashing
On
Off
Slow: Network pattern test active
Fast: Loopback arming
Loopback toward network enabled
Loopback toward network disabled, network pattern test disabled
CUST LOS/AIS
Red
Amber
On
On
Off
DS3 signal not present at customer interface
AIS present at customer interface
DS3 signal present at customer interface
CUST C-BIT
Green
On
Off
C-Bit framing detected at customer interface
C-Bit framing not detected at customer interface
CUST M13
Green
On
Off
M13 framing detected at customer interface
M13 framing not detected at customer interface
CUST LBK
Amber
Flashing
Flashing
On
Off
Slow: Customer pattern test active
Fast: Loopback arming
Loopback toward customer enabled
Loopback toward customer disabled, customer pattern test disabled
FUSE ALARM
Red
Off
On
Normal
Circuit board fuse failed
Note: All LEDs
off
indicates no power or other system malfunction.