Introduction
61247026L1-5A
3
Compliance
The T200 HTU-R, SP/60 mA is NRTL Listed to the applicable UL safety standards for use in
continuous environmental conditions ranging from –40°C to +50°C. Care should be exercised
when handling equipment when temperatures at these extremes exist, as surfaces could be
very cold or hot.
The T200 HTU-R, SP/60 mA meets or exceeds all the applicable requirements of NEBS,
Telcordia GR-63-CORE and GR-1089-CORE and is evaluated to ensure proper operational
performance is maintained if environmental conditions ranging from –40°C to +71°C are
encountered.
The T200 HTU-R, SP/60 mA is intended for deployment in Central Office type facilities, EEEs,
EECs, and locations where the NEC applies (for example, customer premises). Install the T200
HTU-R, SP/60 mA in the appropriate chassis, which is intended to be installed only in
Restricted Access Locations by qualified personnel.
The compliance codes for the T200 HTU-R, SP/60 mA are listed below in
.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
WARNING
Voltages up to –200 VDC with respect to ground may be present on
the HDSL telecommunications conductors. Voltages up to 200
VDC may be present between individual HDSL telecommunications
conductors.
Table 2. T200 HTU-R, SP/60 mA Compliance Codes
Configuration Code
Input
Output
Power Code (PC)
C
C
Telecommunication Code (TC)
X
X
Installation Code (IC)
A
–