Installation
61247026L1-5A
9
Provisioning
Provisioning is performed via software. For more information, refer to
on page 11.
The provisioning settings can be viewed and manipulated through management access via the
front panel RS-232 port.
lists the available provisioning options and their factory
default settings.
Table 6. T200 HTU-R, SP/60 mA Provisioning Defaults
Option
Settings
Default
DSX 1 LBO
0–133 feet; 133–266 feet; 266–399 feet;
399–533 feet; 533–655 feet; EXT
(1)
0-133 feet
DSX-1/DS1 Line Code
B8ZS; AMI
B8ZS
DSX-1/DS1 Framing
AUTO; UNF; Forced Conversion ESF; SF
AUTO
NIU Loopback
Enabled; Disabled
Enabled
New England 1:6 LPBK
Enabled; Disabled
Disabled
Loopback Timeout
NONE; 60 MIN; 120 MIN
120 MIN
Customer Loss Response
AIS; CDI; LPBK
AIS
Latching Loopback Mode
T1; FT1
T1
Performance Reporting Message
(PRM)
NPRM; SPRM; NONE; AUTO
AUTO
DS1 TX LVL
0 dB; –15 dB
0 dB
DS0 Blocking (XX= blocked)
(2)
None blocked;
Any of 01-24 blocked or unblocked
None blocked
1. EXT option only available when using 220 HTU-C (1247001Lx). EXT is the default setting when using the 220
HTU-C.
2. DS0 Blocking is an option that is only valid for the HTU-C and is not configurable on the HTU-R user interface.