Menu Descriptions
61247026L1-5A
17
Current System Status Screen
The Current System Status screen, illustrated in
, provides quick access to status
information for both the T200 HTU-R, SP/60 mA and the HTU-C.
Figure 6. Current System Status Screen
Press “
Z
” at the Current System Status screen in order to reset the current performance
registers to zero on both the Current System Status and Performance History screens. A
prompt requires user confirmation to execute the zero registers function.
The signal quality meters also display
MIN
and
MAX
labels to indicate historical signal quality
performance. The
MIN
and
MAX
registers can be reset by pressing “
X
.”
and
consolidate current information for the HDSL, DSX-1, and DS1 interfaces. A
key to the information provided is found in the center of the screen and defined in
below. Arrows indicate the key applies to both the T200 HTU-R, SP/60 mA and the HTU-C.
Circuit ID:HNTSVLALHDSL MM/DD/YY hh:mm:ss
LOOP #1 <NETWORK> LOOP #2
CURRENT SYSTEM STATUS LOOP #1 <CUSTOMER> LOOP #2
----------HTU-C---------- -----------HTU-R----------
29(29) dB 29(29) dB <- LOSS (CUR MAX) -> 29(29) dB 30(30) dB
YES YES <- SYNC -> YES YES
000/00000 000/00000 <- ES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <- SES 15M/24H -> 000/00000 000/00000
839/00839 865/00865 <- UAS 15M/24H -> 838/00838 865/00865
LOOPBACKS INACTIVE LOOPBACKS INACTIVE
DSX-1 DS1
HTU-C MARGIN (dB) ------------------------------- HTU-R MARGIN (dB)
CUR/MIN/MAX ESF <- FRAME -> ESF CUR/MIN/MAX
B8ZS <- CODE -> B8ZS
LP1 17/17/17 EXT <- LBO -> 0 dB LP1 17/17/17
LP2 17/17/17 N/A <- NIU -> NO LP2 17/17/17
00002 <- BPV -> 00000
00002 <- ES -> 00000
00000 <- SES -> 00000
00096 <- UAS -> 00931
NONE <- ALARMS -> NONE
Press “Z” to zero registers, “X” to restart MIN/MAX, “M” for Main Menu,
“H” for HDSL Range Extender #1 (HRE) View.