Chapter 5. Configuration Menu
5-10
TSU LT User Manual
61202060L2-1
CTS
Used to control characteristics of CTS.
Choices: NORMAL (see Table 5-1), FORCE ON
DCD
Data Carrier Detect - Indicates to the DTE when a valid
signal is being received at the Network Interface.
Choices: NORMAL (see Table 5-1), FORCE ON
DSR
Data Set Ready - This signal indicates to the DTE when the
DCE is turned
ON
and ready for operations.
Choices: NORMAL (see Table 5-1) or FORCE ON
Table 5-1. Normal Mode Operation
INBAND
Inband Configuration Channel - Used to enable/disable an
8 kbps remote configuration channel. See Figure 5-7 on page
5- 11). When this option is set to
ON
, the first DS0 occupied
operates in 56K mode and the DTE clock rate is reduced by 8
kbps. The TSU LT uses this 8 kbps channel to send and
receive configuration data across a T1 span. As shown in
Figure 5-7 on page 5- 11, this allows the PC connected to the
chain-in port on TSU LT A to monitor/configure both TSU
LT A and B. This feature is useful when FDL connectivity is
not available across the T1 span.
NORMAL MODE OPERATION
Conditions which cause the Port Control Signals to be deactivated
SIGNAL
RTS
V.54
LOOP
BK
511 TST
ON
SELF-TEST
ACTIVE
NETWK TEST
ACTIVE
NO DS0
MAPPED
NETWORK
ALARM
CTS
Follows OFF
OFF
OFF
OFF
OFF
OFF
DCD
—
—
—
OFF
—
OFF
OFF
DSR
—
OFF
OFF
OFF
OFF
OFF
—
Where “ — “ = don’t care
Содержание 1202060L2-1
Страница 1: ...TSU LT User Manual Part Number 1202060L2 1 Document Number 1202060L2 1 February 1999...
Страница 16: ...List of Tables xvi TSU LT User Manual 61202060L2 1...
Страница 28: ...Chapter 1 Introduction 1 12 TSU LT User Manual 1202060L2 1...
Страница 44: ...Chapter 4 Status Menu 4 6 TSU LT User Manual 61202060L2 1...
Страница 56: ...Chapter 5 Configuration Menu 5 12 TSU LT User Manual 61202060L2 1...
Страница 60: ...Chapter 6 Utility Menu 6 4 TSU LT User Manual 61202060L2 1...
Страница 72: ...Chapter 8 Example Operations 8 6 TSU LT User Manual 61202060L2 1...
Страница 76: ...Appendix B DTE Data Rate Chart B 2 TSU LT User Manual 61202060L2 1...
Страница 86: ......