Chapter 7. Test Menu
7-4
TSU LT User Manual
61202060L2-1
TEST PATTERN
Sets the pattern for the test and initiates the transmission of
the pattern. There are four patterns available. The test is
terminated by selecting
NO PATTERN
.
1:8 ALL DS0s
Generates a 1 in 8 pattern in all DS0s.
511 Active DS0s
Generates a 511 test pattern and inserts the pattern into
currently active channels.
All Zeros
Generates an all zero's pattern in every channel.
All Ones
Generates an all one’s pattern in every channel.
CLR ERRORS
CLR
ERRORS
has two functions.
1. It clears out the 511 error total when you press
Enter
.
2. It displays a total of the 511 errors. If 511 errors are being
received, the display is updated accordingly. See Figure
7-3.
Figure 7-3. Clear Errors Screen
This menu function is very useful for testing end-to-end
integrity of the network. First loop up the far end TSU LT.
Then send a 511 pattern from the local TSU LT. The
CLR
ERRORS
screen can then be used to determine if the link is
Содержание 1202060L2-1
Страница 1: ...TSU LT User Manual Part Number 1202060L2 1 Document Number 1202060L2 1 February 1999...
Страница 16: ...List of Tables xvi TSU LT User Manual 61202060L2 1...
Страница 28: ...Chapter 1 Introduction 1 12 TSU LT User Manual 1202060L2 1...
Страница 44: ...Chapter 4 Status Menu 4 6 TSU LT User Manual 61202060L2 1...
Страница 56: ...Chapter 5 Configuration Menu 5 12 TSU LT User Manual 61202060L2 1...
Страница 60: ...Chapter 6 Utility Menu 6 4 TSU LT User Manual 61202060L2 1...
Страница 72: ...Chapter 8 Example Operations 8 6 TSU LT User Manual 61202060L2 1...
Страница 76: ...Appendix B DTE Data Rate Chart B 2 TSU LT User Manual 61202060L2 1...
Страница 86: ......