background image

Chapter 2. Installation

61200.184L1-1

Quad Nx 56/64 Module User Manual

5

 

WIRING

 

Each port of the Quad Nx 56/64 Module has a V.35 Winchester-style 

connection (via the supplied adapter cables) as defined in Table 2-A.

 

Table 2-A

 

V.35 Winchester Pin Connection

 

POWER-UP TESTING AND INITIALIZATION

 

The Quad Nx 56/64 Module executes a self test during the power-up 

sequence, as described in the 

 

ATLAS 800 User Manual

 

. Upon power-up, 

any previously configured setting for the Quad Nx 56/64 Module is auto-

matically restored.

When the self test is completed and the configuration is successfully 

restored, the LED labeled OK in the Module group on the front panel 

turns On.  If any alarms are detected during operation, the red LED 

labeled ALARM in the Module group on the front panel turns On. 

If the power-up self test is not successful, refer to the

 

 Troubleshooting 

 

sec-

tion of the 

 

ATLAS 800 User Manual

 

 to diagnose and correct the problem.

Return to Chapter 2 (Installation) of the 

 

ATLAS 800 User Manual

 

 to con-

tinue system set-up.

  

                 DESCRIPTION

Protective ground (PG)
Signal ground (SG)
Request to send (RTS) from DTE
Clear to send (CTS) to DTE
Data set ready (DSR) to DTE
Received line signal detector (DCD) to DTE
Data terminal ready (DTR) from DTE*
Ring indicator (RI)*
Local loopback (LL) from DTE*
Remote loopback (RL) from DTE*
Received data (RD-A) to DTE
Received data (RD-B) to DTE
RX clock (RC-A) to DTE
RX clock (RC-B) to DTE
Transmitted data (TD-A) from DTE
Transmitted data (TD-B) from DTE
TX clock (TC-A) to DTE
TX clock (TC-B) to DTE
External TX clock (ETC-A) from DTE
External TX clock (ETC-B) from DTE
Test mode (TM) to DTE

CCITT

101
102
105
106
107
109

-
-
-
-

104
104
115
115
103
103
114
114
113
113

-

Pin

A
B
C
D
E
F
H

J
L

N
R

T
V
X
P
S
Y

AA

U

W

NN

* Ignored by Quad Nx 56/64 Module  

Содержание 1200184L1

Страница 1: ...Quad Nx 56 64 Module Part Number 1200184L1 USER MANUAL 61200 184L1 1A November 1997...

Страница 2: ...901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 205 963 8000 1997 ADTRAN Inc All Rights Reserved Printed in U S A...

Страница 3: ...d can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio frequencies Operation of this equipment in a reside...

Страница 4: ......

Страница 5: ...ADTRAN Shipments Include 3 Customer Provides 3 Installing the Quad Nx 56 64 Module 4 Wiring 5 Power Up Testing and Initialization 5 Chapter 3 Operation 7 Overview 7 TERMINAL Menu Structure 7 Menu Desc...

Страница 6: ...ta Format 12 CTS 13 DCD 13 DSR 13 DTR 13 0 Inh Zero Inhibit 13 Test 14 Loopbk 14 Loopback Status 14 511 511 Test Pattern 14 511 Result 14 Inject Inject Error 15 511 Clr Clear Results 15 Appendix A Qua...

Страница 7: ...Each port operates using 1 to 24 DS0s Includes an elastic store for absorption of rate variations Any port can be used as a timing source for the entire system Outputs a 50 percent duty cycle output...

Страница 8: ...onvert to Winchester female connectors Physical Description The Quad Nx 56 64 Module can plug into any available option slot in the ATLAS 800 chassis see Figure 1 1 The module has an indication under...

Страница 9: ...e last page of this manual for infor mation on contacting Technical Support If possible keep the original shipping container for use in shipping the option module back for repair or for verification o...

Страница 10: ...slot in which the Quad Nx 56 64 Module will be installed from the ATLAS 800 chassis rear panel 2 Slide the Quad Nx 56 64 Module into the ATLAS 800 chassis until the module is positioned firmly against...

Страница 11: ...anel turns On If the power up self test is not successful refer to the Troubleshooting sec tion of the ATLAS 800 User Manual to diagnose and correct the problem Return to Chapter 2 Installation of the...

Страница 12: ...Chapter 2 Installation 6 Quad Nx 56 64 Module User Manual 61200 184L1 1...

Страница 13: ...User Manual In order to edit items in the terminal menus you must have the appropriate pass word level Each menu description in this section indicates the required password level required for write a...

Страница 14: ...0 refers to the ATLAS 800 base unit This field is read only Type Write security 3 Read security 5 Displays the type of module actually installed in the slot or the type of module you plan to install...

Страница 15: ...is parameter allows an installed module to be marked Offline which may be useful in system troubleshooting Status Read security 5 This is a read only field presenting status information on the Quad Nx...

Страница 16: ...the module Part Number Displays the part number of the module This field is read only Serial Number Displays the Quad Nx 56 64 Module s serial number This field is read only Quad Nx Alarms Read secur...

Страница 17: ...ead only RTS Request To Send from DTE CTS Clear To Send to DTE DTR Data Terminal Ready from DTE DSR Data Set Ready to DTE DCD Data Carrier Detect to DTE RI Ring Indicate to DTE TD Transmit Data from t...

Страница 18: ...urity 5 Controls the clock used by the Quad Nx 56 64 Module to accept the trans mit TX data from the DTE This is usually set to Normal If the interface cable is long causing a phase shift in the data...

Страница 19: ...curity 3 Read security 5 Data Terminal Ready This parameter determines whether the ATLAS 800 treats a connection as permanent DTR Ignore or to connect only when DTR is active DTR Connect On DTR Select...

Страница 20: ...ed Port looped from remote source Port loopback active 511 511 Test Pattern Write security 4 Read security 5 Controls the activation of the 511 test pattern generator and detector 511 Result Read secu...

Страница 21: ...0 184L1 1 Quad Nx 56 64 Module User Manual 15 Inject Inject Error Write security 4 Read security 5 Injects a 511 pattern error 511 Clr Clear Results Write security 4 Read security 5 Clears test result...

Страница 22: ...Chapter 3 Operation 16 Quad Nx 56 64 Module User Manual 61200 184L1 1...

Страница 23: ...Dial Plan menu sets configura tion parameters for the end point These parameters will vary by the type of port selected The following section describes the configuration options available for the Qua...

Страница 24: ...n options are available Ports Available Indicates which of the four ports of the Quad Nx56 64 module have already been defined either in another switched end point indicated by s or in a Dedicated Map...

Страница 25: ...ysical 2 dial plan configuration 17 DSR 11 13 DTE status 11 DTR 11 F features 1 H hardware revision 9 I inband 11 initialization 5 inject error 15 installation 3 installing the module 4 interface conf...

Страница 26: ...s 10 overview 1 physical description 2 specifications 2 Quad Nx alarms 10 Quad Nx info 10 R RD 11 remote loopback 14 RI 11 RTS 11 S self test 14 slip 10 specifications 2 state 9 status 9 alarm 10 T TD...

Страница 27: ...l Support determines that a repair is needed Technical Support will coordi nate with the Return Material Authorization RMA department to issue an RMA number For in formation regarding equipment curren...

Отзывы: