Appendix A: Nx 56/64 Dial Plan Interface Configuration
18
Quad Nx 56/64 Module User Manual
61200.184L1-1
Nx56/64 Option Module Interface Configuration
This section describes the User Termination configuration settings for the
Quad Nx56/64 Module when using the Dial Plan menus.
The Nx56/64 can only serve as a User termination end point.
Nx56/64 Option Module (User Termination)
When you are working in the User Termination section of the Dial Plan
menu, the Slot is defined as a Nx56/64 module, the following configura-
tion options are available:
Ports Available
Indicates which of the four ports of the Quad Nx56/64 module have
already been defined either in another switched end point (indicated by
“s”) or in a Dedicated Map (indicated by “n”). This field is read-only.
Number of Ports
Defines to ATLAS how many of the ports could be used to answer calls to
the number(s) defined in the Accept Call list. You can enter numbers 1
through 4. The ports are contiguous beginning with the Port number
select and the number of ports.
Example: If the port selected (as a part of Slot/Port selection) is 2, and the
number of ports selected here was 2, then ports 2 and 3 would be enabled
to receive calls to the numbers listed under the Incoming Call Accept list.